Regarding the indicator lamps

When the LAMP, TEMP and POWER indicators are acting unusual, review the
following table.
POWER
LAMP
indicator
indicator
Solid
OFF
Orange
Blinking
OFF
Green
Solid
OFF
Green
Blinking
OFF
Orange
Blinking
(discre-
Red
tionary)
Blinking
or
Solid
Solid
Red
Red
Blinking
or
Blinking
Solid
Red
Red
(continued on next page)
TEMP
indicator
The projector is in a standby state.
OFF
Refer to the section "Power on/off".
The projector is warming up.
OFF
Please wait.
The projector is in an ON state.
OFF
Normal operations can be performed.
The projector is cooling down.
OFF
Please wait.
The projector is cooling down. An error has
(discre-
been detected.
tionary)
Please wait until the POWER indicator finishes
blinking, and then follow the directions below.
The lamp does not light, and the inside of the
projector may be overheated.
Turn the power off, and allow the projector to cool
down at least 20 minutes. After the projector has
cooled down sufficiently, verify the following items,
and then turn the power on again.
• Are the vents blocked?
OFF
• Is the air filter dirty?
• Does the peripheral temperature exceed 45°C?
• If you are using an IN5132, IN5134, IN5134a or
IN5135, does the peripheral temperature exceed
40°C?
If indicators are doing the same thing, change the
lamp according to section Replacing the lamp.
The lamp cover has not been securely
fastened.
Turn the power off, and allow the projector to cool
down at least 45 minutes. After the projector has
OFF
cooled down sufficiently, verify the attachment state
of the lamp cover. After performing any needed
maintenance, turn the power on again. If the
indicators are doing the same thing, contact your
dealer or service company.