Maintenance
Cleaning and replacing the air filter (continued)
10.
Put the filter cover back into the place.
11.
Turn the projector on and reset FILTER TIME in the EASY MENU.
(1) Press the MENU button to display a menu.
(2) Highlight FILTER TIME using the ▲/▼ cursor buttons, then press the ►
cursor (or the ENTER / the RESET) button. A dialog will appear.
(3) Press the ► cursor button to select OK on the dialog. It resets the filter
time.
WARNING
unplugged, then allow the projector to cool sufficiently.
►Only use the specified air filter. Do not use the projector without an air filter or
the filter cover. It could result in a fire or projector malfunction.
►Clean the air filter periodically. If the air filter becomes clogged by dust or
the like, internal temperatures rise and could cause a fire, burns or a projector
malfunction.
NOTE
• Reset the filter time only after you have cleaned or replaced the air
filter in order to maintain accurate air filter information.
• The projector may display a message such as the "CHECK THE AIR FLOW"
or turn off the projector to prevent the projector from overheating.
► Before maintaining the air filter, verify the power cable is
111