1) Connector
Printer side :
25-pin receptacle
Type DB-25S (made by Canon) or equivalent
Cable side :
25-pin plug
Type DB-25S (made by Canon)
Shell
Type DB-C8-J10-F2-1 (made by Nihon Kouku Denshi) or equivalent
Note: Plug shall be fixable with a lock screw.
2) Cable
Cable length :
6 ft (1.8 m) max. (cable shall be shielded)
Note: Cable is not provided. Cable is not provided.
3) Interface signal
Pin No.
Signal name
1
Frame Ground
2
Transmitted Data
3
Received Data
4
Request to Send
5
---
6
---
7
Signal Ground
9 to 17
---
18
---
19
---
20
Data Terminal Ready
21 to 25
---
Connector pin arrangement
(View from cable side)
Service Manual - OKIPAGE10i
Chapter A RS-232C Serial Interface (Option)
Abbreviation
FG
TD
RD
RTS
SG
DTR
Signal
Functions
direction
Frame Ground
<-- PR
Transmitted Data
--> PR
Receive Data
<-- PR
Stay space level
(Not connected)
(Not connected)
Signal Ground
(Not connected)
(Not connected)
(Not connected)
<-- PR
Data terminal ready
(Not connected)