Problem or status
Code
Error
(nn)
71
A failure occurred with the fuser
(timeout error etc).
72
A failure occurred with the fuser
(thermistor open error).
73
A failure occurred with the fuser
(thermistor short error).
74
SSIO Error
77
A toner sensor fault has
occurred when the TOTAL
DRUM COUNT is 30 or less.
80
I/F timeout occurred between
the main control board and the
operator panel.
81
90
91
F0
F1
Remedy
See Section 6.5.2-(4).
See Section 6.5.2-(4).
See Section 6.5.2-(4).
- Check the connection
between the main control
board and the power
supply/sensor board.
- Replace the main control
board or power
supply/sensor board.
- Check the installing of
image drum unit.
- Replace the power
supply/sensor board.
- Check the operator
panel for proper
connection.
- Replace the flexible
cable, operator panel or
main control board.
See Section 6.5.2-(5).
- Turn the power off, then
back on again.
- Replace the main control
board.
Note: When replaced the
main control board, be
sure to install the
EEPROM from the old
board to the new board.