Server family and its components
Hide thumbs Also See for S8510:
Table of Contents

Advertisement

Code
E1313
E1410
E1414
E1418
E141C
E141F
E1420
Installing the Avaya S8510 Server Family and Its Components
Text
Fan
The system is no
Redundancy
longer fan-
redundant. Another
fan failure will put the
system at risk of over-
heating.
CPU # IERR
Specified
microprocessor is
reporting an internal
error.
CPU #
Specified
Thermtrip
microprocessor is
out of acceptable
temperature range
and has halted
operation.
CPU #
Specified processor
Presence
is missing or bad,
and the system is in
an unsupported
configuration.
CPU
Processors are in an
Mismatch
unsupported
configuration.
CPU Protocol
The system BIOS
has reported a
processor protocol
error.
CPU Bus
The system BIOS
PERR
has reported a
processor bus parity
error.
Causes
Check room temperature
and external air flow. If both
are within acceptable limits,
then escalate for possible
server replacement.
Check control panel LCD
for additional scrolling
messages.
Escalate for possible
server replacement.
Check room temperature
and external air flow. If both
are within acceptable limits,
then escalate for possible
server replacement.
The LCD continues to
display this message
until the system's power
cord is disconnected and
reconnected to the AC
power source.
Escalate for possible
server replacement.
Run server diagnostics.
This requires a keyboard
and monitor.
Escalate for possible
server replacement.
Escalate for possible
server replacement.
LCD status message explanations
Corrective Action
Note: