Avaya S8510 Installation Manual page 30

Server family and its components
Hide thumbs Also See for S8510:
Table of Contents

Advertisement

Status messages
Code
E1714
E171F
E1810
E1811
E1812
E1913
E1A14
E1A15
32
Installing the Avaya S8510 Server Family and Its Components
Text
Unknown Err
The system BIOS
has determined that
there has been an
error in the system,
but is unable to
determine its origin.
PCIE Fatal Err
The system BIOS
B## D## F##
has reported a PCIe
fatal error on a
component that
resides in PCI
configuration space
at bus ##, device ##,
function ##.
PCIE Fatal Err
The system BIOS
Slot #
has reported a PCIe
fatal error on a
component that
resides in the
specified slot.
HDD ## Fault
The SAS subsystem
has determined that
hard drive ## has
experienced a fault.
HDD ## Rbld
The specified hard
Abrt
drive has
experienced a
rebuild abort.
HDD ##
The specified hard
Removed
drive has been
removed from the
system.
CPU &
The BMC firmware
Firmware
does not support the
Mismatch
CPU.
SAS Cable A
SAS cable A is
missing or bad.
SAS Cable B
SAS cable B is
missing or bad.
Causes
Escalate for possible
server replacement.
Reseat all PCIe cards, then
reboot the system. If the
problem persists, escalate
for possible server
replacement.
Escalate for possible hard
drive replacement.
Escalate for possible hard
drive replacement.
Information only.
Escalate for possible
server replacement.
Escalate for possible
server replacement.
Escalate for possible
server replacement.
Corrective Action
May 2008

Advertisement

Table of Contents
loading