Avaya S8510 Installation Manual page 26

Server family and its components
Hide thumbs Also See for S8510:
Table of Contents

Advertisement

Status messages
Code
E1000
E1114
E1116
E12nn
E1210
E1211
E1229
E1310
E1311
28
Installing the Avaya S8510 Server Family and Its Components
Text
FAILSAFE,
Call Support
Temp Ambient
Ambient system
temperature is out of
acceptable range.
Temp Memory
Memory has
exceeded
acceptable
temperature and has
been disabled to
prevent damage to
the components.
xx PwrGd
Specified voltage
regulator has failed.
CMOS Batt
CMOS battery is
missing, or the
voltage is out of
acceptable range.
ROMB Batt
RAID battery is
either missing, bad,
or unable to
recharge due to
thermal issues.
CPU #
Processor # VCORE
VCORE
voltage regulator has
failed.
RPM Fan ##
RPM of specified
cooling fan is out of
acceptable operating
range.
RPM Fan Mod
RPM of fan x in the #
#x
module is out of
acceptable operating
range.
Causes
Escalate for possible
server replacement.
Check room temperature
and external air flow. If both
are within acceptable limits,
then escalate for possible
server replacement.
Check room temperature
and external air flow. If both
are within acceptable limits,
then escalate for possible
server replacement.
Escalate for possible
server replacement.
Shut down server for 1
hour and disconnect the
power supply. If problem
continues, escalate for
possible server
replacement.
Check room temperature
and external air flow. If both
are within acceptable limits,
then escalate for possible
server replacement.
Escalate for possible
server replacement.
Check room temperature
and external air flow. If both
are within acceptable limits,
then escalate for possible
server replacement.
Check room temperature
and external air flow. If both
are within acceptable limits,
then escalate for possible
server replacement.
Corrective Action
May 2008

Advertisement

Table of Contents
loading

Table of Contents