Text
SBE Log
The system BIOS
Disable Crd #
has disabled
DIMM ##
memory single-bit
error (SBE) logging,
and will not resume
logging further SBEs
until the system is
rebooted. "##"
represents the DIMM
implicated by the
BIOS. If no memory
riser card is present,
the "Crd #" string is
left out of the
message.
Mem Spare
The system BIOS
Crd # DIMM
has spared the
##
memory because it
has determined that
the memory had too
many errors. "## &
##" represents the
DIMM pair implicated
by the BIOS. If no
memory card is
present, the "Crd #"
string is left out of
the message.
Mem Mirror
The system BIOS
Crd # DIMM
has disabled
## & ##
memory mirroring
because it has
determined that one
half of the mirror has
had too many errors.
"## & ##" represents
the DIMM pair
implicated by the
BIOS. If no memory
card is present, the
"Crd #" string is left
out of the message.
Causes
Escalate for possible
server replacement.
Escalate for possible
memory or server
replacement.
Escalate for possible
memory or server
replacement.
LCD status message explanations