Removing Lcd Status Messages - Avaya S8510 Installation Manual

Server family and its components
Hide thumbs Also See for S8510:
Table of Contents

Advertisement

Status messages
Code
E2118
E2119
I1910
I1911
I1912
W1228

Removing LCD status messages

For faults associated with sensors, such as temperature, voltage, fans, and so on, the LCD
message is automatically removed when that sensor returns to a normal state. For example,
if temperature for a component goes out of range, the LCD displays the fault; when the
temperature returns to the acceptable range, the message is removed from the LCD. For
other faults, you must take action to remove the message from the display.
36
Installing the Avaya S8510 Server Family and Its Components
Text
Fatal NB Mem
One of the
CRC
connections in the
FBD memory
subsystem link on
the Northbound side
has failed.
Fatal SB Mem
One of the
CRC
connections in the
FBD memory
subsystem link on
the Southbound side
has failed.
Intrusion
System cover
removed.
>3 ERRs Chk
LCD overflow
Log
message. A
maximum of three
error messages can
display sequentially
on the LCD. The
fourth message
displays as the
standard overflow
message.
SEL Full
System Event Log is
full of events, and is
unable to log any
more events.
ROMB Batt <
Warns predictively
24hr
that the RAID battery
has less than 24
hours of charge left.
Causes
Escalate for possible
memory or server
replacement.
Escalate for possible
memory or server
replacement.
Information only.
Information only.
Clear the log by deleting
event entries.
Information only.
Corrective Action
May 2008

Advertisement

Table of Contents
loading