If the liquid stored in the spill containment exceeds approximately about 25gal ( 94.6 liters )
during operation, the SPILL CONTAINMENT overflow warning indicator illuminates, and the
engine automatically stops. If this occurs, flush the liquid stored in the spill containment.
(Refer to section "10. Inspection/Maintenance (10) Flushing Liquid in Spill Containment".)
< Note >
 Although the fluids that can leak internally consist of oil, fuel and cooling water, the spill
containment does not have a function that can separate rainwater that has leaked into the
equipment from these internally leaked fluids. Properly dispose of liquid drained from the spill
containment in a manner according to the applicable laws and regulations.

5-6. Meters and Gauges

Engine Meters and Gauges
(1) Hour Meter
Displays the operating time. Use this as a reference for managing periodic inspection
interval. Be careful as the hour meter operates when the starter switch is at RUN regardless
of whether the engine is running.
(2) Engine Monitor
Displays the engine speed, water temperature and oil pressure. Switching the selector
switch changes the display in the following order: Speed  Water temp  Oil press. Engine
speed is displayed first when the engine is started.
 Speed
Displays the engine speed. 1800rpm is displayed
at 60 Hz.
 Water Temp
Displays the temperature of the engine coolant.
Normal temperature displayed during operation
should generally between 167°F (75℃) and 194°F
(90℃) depending on usage.
< Note >
 If the coolant temperature rises above 212 °F(100℃), immediately stop all connected equipment
to the generator, and idle the engine while cool down the coolant temperature.
 Oil Press
Displays the pressure of the engine lubrication system. Normal pressure displayed during
operation should generally between 28 and 85 psi (1.93-5.86 x 100 kPa) depending on
usage. However, the pressure may rise above this range just after starting a cold engine.
Idle the engine until it reaches the normal pressure.
(3) Fuel Meter
Displays the amount of fuel in the internal fuel tank. When the tank is full, all lamps are lit up
and FULL is displayed. The amount of lamps lit up decreases as the amount of fuel
decreases as it approaches EMPTY. Add fuel accordingly when only one lamp is displayed.
The fuel meter on the control panel will only display the fuel level for the internal fuel tank.
14
Oil Press
Water Temp
Speed
Fuel Meter
Selector
Switch
Hour Meter
時間計