5.20

Standard default setting

: Default setting
• Function
This parameter is to set two or more parameters at a time for different commands. Using this parameter, all
parameters can be also return to their respective default settings by one operation, and save or set specific
parameters individually.
[Parameter setting]
Title
Factory default setting
This parameter is used to change the settings of other parameters. Therefore,
cannot be set during the inverter operating. Always stop the inverter first and then program.
When parameter
[Programmed value]
50Hz default setting (
Setting
at
causes all the following parameters to be set for operation using a base frequency of 50Hz.
(This does not change the settings of any other parameters.)
• Maximum frequency
• Base frequency 1
• Base frequency 2
• Base frequency 3
• Base frequency 4
• Upper limit frequency
• Forward speed limit input level
• Reverse speed limit input level
• Commercial power/inverter switching frequency
• Point 2 frequency
• Automatic light-load high-speed operation frequency
60Hz default setting (
Setting
at
causes all the following parameters to be set for operation using a base frequency of 60Hz.
(This does not change the settings of any other parameters.)
• Maximum frequency
• Base frequency 1
• Base frequency 2
• Base frequency 3
• Base frequency 4
• Upper limit frequency
• Forward speed limit input level
• Reverse speed limit input level
• Commercial power/inverter switching frequency
• Point 2 frequency
• Automatic light-load high-speed operation frequency
Function
: –
:50Hz default setting
:60Hz default setting
:Factory default setting
:Trip clear
:Cumulative operation time cleared
:Initialization of type information
:Save user-defined parameters
:Reset of user-defined parameters
:Cumulative fan operation time record clear
:Acceleration/deceleration time setting
0.01 sec.~600.0 sec.
:Acceleration/deceleration time setting 0.1
sec.~6000 sec.
is invoked, the value set previously is displayed on the left side of the parameter.
= )
: 50Hz
: 50Hz
: 50Hz
: 50Hz
: 50Hz
: 50Hz
: 50Hz
: 50Hz
: 50Hz
: 50Hz
: 50Hz
= )
: 60Hz
: 60Hz
: 60Hz
: 60Hz
: 60Hz
: 60Hz
: 60Hz
: 60Hz
: 60Hz
: 60Hz
: 60Hz
E-41
Adjustment range
is always displayed.
• VI/II input point 2 frequency
• RR/S4 input point 2 frequency
• RX input point 2 frequency
• AI1 input point 2 frequency
• AI2 input point 2 frequency
• RP/high-speed pulse input point 2 frequency
• PID deviation upper limit
• PID deviation lower limit
• Process upper limit
• PID output upper limit
• Motor rated revolutions (motor name plate)
• VI/II input point 2 frequency
• RR/S4 input point 2 frequency
• RX input point 2 frequency
• AI1 input point 2 frequency
• AI2 input point 2 frequency
• RP/high-speed pulse input point 2 frequency
• PID deviation upper limit
• PID deviation lower limit
• Process upper limit
• PID output upper limit
• Motor rated revolutions (motor name plate)
E6581301
Default setting
5
: 50Hz
: 50Hz
: 50Hz
: 50Hz
: 50Hz
: 50Hz
: 50Hz
: 50Hz
: 50Hz
: 50Hz
:1410min-1
: 60Hz
: 60Hz
: 60Hz
: 60Hz
: 60Hz
: 60Hz
: 60Hz
: 60Hz
: 60Hz
: 60Hz
:1710min-1