[22] Acceleration/deceleration 2 [2/2]
Communi
Title
cation
Function
No.
0514
Acceleration time 4
0515
Deceleration time 4
Acceleration/ deceleration 4
0516
pattern
Acceleration/deceleration
0517
switching frequency 3
*1: Default values vary depending on the capacity. ⇒ See the table of K-46.
*2: Changing the parameter
enables to set to 0.01 sec. (adjustment range: 0.01~600.0 sec.).
[23] Pattern operation [1/3]
Communi
Title
cation
Function
No.
0520
Pattern operation selection
0521
Pattern operation mode
Number of repetitions of pattern
0522
group 1
0523
Pattern group 1 selection 1
0524
Pattern group 1 selection 2
0525
Pattern group 1 selection 3
0526
Pattern group 1 selection 4
0527
Pattern group 1 selection 5
0528
Pattern group 1 selection 6
0529
Pattern group 1 selection 7
0530
Pattern group 1 selection 8
Number of repetitions of pattern
0531
group 2
0532
Pattern group 2 selection 1
0533
Pattern group 2 selection 2
0534
Pattern group 2 selection 3
0535
Pattern group 2 selection 4
0536
Pattern group 2 selection 5
0537
Pattern group 2 selection 6
0538
Pattern group 2 selection 7
0539
Pattern group 2 selection 8
Adjustment range
0.1~6000 sec.
0.1~6000 sec.
0:Straight, 1:S-pattern 1, 2:S-pattern 2
0.0~
Hz
Adjustment range
0:Deselect
1:Select (setting in units of seconds)
2:Select (setting in units of minutes)
0:Pattern operation reset when system stops
operation
1:Pattern operation continued even after system
stops operation
1~254, 255:∞
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
1~254, 255:∞
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
0.1/0.1 *2
*1
Enabled
●/●
0.1/0.1 *2
*1
Enabled
●/●
1/1
0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
1
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
1
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
PM
Torque
V/f Constant Reference
control
control
-
6. 30. 1
-
6. 30. 1
-
6. 30. 1
-
6. 30. 1
PM
V/f Constant Reference
Torque
control
control
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31

Advertisement

Table of Contents
loading

Table of Contents