Snmp Traps - ZyXEL Communications MGS-3712/MES-3728 User Manual

Layer 2+ metro ethernet switch
Table of Contents

Advertisement

Chapter 34 Access Control

34.3.3 SNMP Traps

The Switch sends traps to an SNMP manager when an event occurs. The following
tables outline the SNMP traps by category.
An OID (Object ID) that begins with "1.3.6.1.4.1.890.1.5.8" is defined in private
MIBs. Otherwise, it is a standard MIB OID.
Table 103 SNMP System Traps
OPTION
OBJECT LABEL
coldstart
coldStart
warmstart
warmStart
fanspeed
FanSpeedEventOn
FanSpeedEventClear
temperatur
TemperatureEventOn
e
TemperatureEventClear
voltage
VoltageEventOn
VoltageEventClear
reset
UncontrolledResetEventO
n
ControlledResetEventOn
RebootEvent
timesync
RTCNotUpdatedEventOn
RTCNotUpdatedEventClea
r
308
OBJECT ID
1.3.6.1.6.3.1.1.5.1
1.3.6.1.6.3.1.1.5.2
1.3.6.1.4.1.890.1.5.8.45.2
7.2.1
1.3.6.1.4.1.890.1.5.8.45.2
7.2.2
1.3.6.1.4.1.890.1.5.8.45.2
7.2.1
1.3.6.1.4.1.890.1.5.8.45.2
7.2.2
1.3.6.1.4.1.890.1.5.8.45.2
7.2.1
1.3.6.1.4.1.890.1.5.8.45.2
7.2.2
1.3.6.1.4.1.890.1.5.8.45.2
7.2.1
1.3.6.1.4.1.890.1.5.8.45.2
7.2.1
1.3.6.1.4.1.890.1.5.0.1
1.3.6.1.4.1.890.1.5.8.45.2
7.2.1
1.3.6.1.4.1.890.1.5.8.45.2
7.2.2
DESCRIPTION
This trap is sent when the
Switch is turned on.
This trap is sent when the
Switch restarts.
This trap is sent when the fan
speed goes above or below the
normal operating range.
This trap is sent when the fan
speed returns to the normal
operating range.
This trap is sent when the
temperature goes above or
below the normal operating
range.
This trap is sent when the
temperature returns to the
normal operating range.
This trap is sent when the
voltage goes above or below
the normal operating range.
This trap is sent when the
voltage returns to the normal
operating range.
This trap is sent when the
Switch automatically resets.
This trap is sent when the
Switch resets by an
administrator through a
management interface.
This trap is sent when the
Switch reboots by an
administrator through a
management interface.
This trap is sent when the
Switch fails to get the time and
date from a time server.
This trap is sent when the
Switch gets the time and date
from a time server.