Turning Off the System Alarm Relay

For carrier-mounted iMarc units, an alarm system relay is provided by the 9000
Series Access Carrier. This relay activates a light or buzzer when an alarm
condition is detected in one of the iMarc units.
Once the alarm relay is connected, enabling the System Alarm Relay option
activates this feature (see the
Once activated, the relay is turned off in one of the following ways:
See Alarm Relay Connector in the 9000 Series Access Carrier Installation
Instructions for information about connecting the alarm relay.
9000-A2-GB33-20
The alarm condition that activated the relay no longer exists. The relay stays
on until all alarm conditions have been corrected.
The System Alarm Relay option can be disabled.
Main Menu→Configuration→System→General
System Alarm Relay Cut-Off can be selected.
Main Menu→Control→System Alarm Relay Cut-Off
May 2003
4. Operation and Maintenance
iMarc SLV Configuration
Reference).