Physical Tests (9123, 9126, 9128) - Paradyne iMarc SLV Operation Manual

Imarc slv
Table of Contents

Advertisement

Physical Tests (9123, 9126, 9128)

Physical tests require the participation of your network service provider.
If the unit does not have the ISDN PRI DBM feature, PRI Physical Tests does not
appear.
An iMarc unit's physical tests screen for the network interface is shown below.
The InjectErr function key at the bottom of the screen only appears when a Send
Pattern Test is Active. Select InjectErr to inject a single bit error into the pattern
being sent.
The ResetMon function key at the bottom of the screen only appears when a
Monitor 511 test pattern is Active. Select ResetMon to reset the monitor pattern
error counter.
9000-A2-GB33-20
Main Menu→Test→[Network Physical Tests/Data Port Physical Tests/
DSX-1 Physical Tests/PRI Physical Tests]
Physical Tests Screen Example
main/test/network
Device Name: Node A
Test
Local Loopbacks
Line Loopback:
Payload Loopback:
Repeater Loopback:
Remote Loopbacks
Send Line Loopback: Down
Pattern Tests
Send:
user-defined 0a0a
Monitor: user-defined0a0a
--------------------------------------------------------------------------------
Ctrl-a to access these functions, ESC for previous menu
InjectErr
ResetMon
CAUTION:
You should not run these tests with frame relay equipment attached;
you must disconnect the frame relay equipment and use external test
equipment.
May 2003
NETWORK 1 PHYSICAL TESTS
Command
Status
Start
Inactive
Start
Inactive
Start
Inactive
Send
Inactive
Stop
Active
Stop
Active
5. Troubleshooting
9128-II
5/26/2000 23:32
Results
0:00:00
0:00:00
0:00:00
0:00:00
0:00:00 - Errors 99999+
0:00:00 - Errors 99999+
MainMenu
Exit
5-29