Verifying That Self-Test Passed; Setting The System Clock - Paradyne FrameSaver SLV 9664 Installation Instructions Manual

Hide thumbs Also See for FrameSaver SLV 9664:
Table of Contents

Advertisement

Verifying that Self-Test Passed

1. Follow this menu selection sequence from the Main Menu and press Enter after
each selection:
Main Menu → Status → System and Test Status
2. Check the Self-Test Results column (in the center of the System and Test Status
screen).
– If Passed appears, the FrameSaver unit successfully completed the self-test.
– If any failure messages appear in this column, reset the unit by disconnecting,
then reconnecting the power cord. The unit will perform the self-test again. If the
failure reappears, call your service representative for assistance.

Setting the System Clock

To set up the system clock:
1. Select System Information.
Main Menu → Control → System Information
2. Move the cursor to the Date, then the Time field to enter:
– Date in the mm/dd/yyyy format (month/day/year)
– Time in the hh:mm:ss format (hours:minutes:seconds)
3. Save the settings.
Assigning the Node IP Address
1. Set up the node.
Main Menu → Configuration → Management and Communication → Node IP
2. Minimally, enter the following options:
– Node IP Address
– Node Subnet Mask
3. Save the configuration.
8

Advertisement

Table of Contents
loading

Table of Contents