Chapter 12 Parameters And Defaults; Bluetooth Communications Parameters - Denso GT10B-SB User Manual

Bar code handy scanner
Table of Contents

Advertisement

Chapter 12 Parameters and Defaults

The tables below list the parameters and their defaults. Those parameter settings can be changed with the bar-coded
parameter menu and configuration software (ScannerSetting), except shadowed ones only with the configuration
software.
When the scanner leaves the factory, all of these parameters are set to defaults.
®
(1) Bluetooth
communications parameters
Items
Communications protocol
Header
Terminator
ACK/NAK response time
Configure the scanner as master or slave
Timeout period for slave to wait for a
connection request
Timeout period for automatic disconnection
®
of the Bluetooth
wireless link
Clear the transfer buffer when the
®
Bluetooth
link breaks
Parameters
Non-acknowledge mode
ACK/NAK mode
Data packaging mode (to host)
Data packaging mode (to BA10-RKU)
None
STX
ETX
CR
LF
CR LF
None
1 to 25 seconds
(0.1 to 9.9 seconds on models that do
not support data packaging)
As a master
As a slave
2 minutes
4 minutes
10 minutes
30 minutes
5 to 640 minutes
Disable automatic disconnection
Enable
Disable
: Can be changed only with the configuration software.
53
Defaults
Refer to:
Section 10.1 (1)
Section 10.2.1 (1)
1 s
Section 10.1 (1)
Section 2.2
Section 10.1 (2)
485 min.
Section 10.1 (3)
Section 10.1 (4)

Advertisement