9.2
Indicator LED
The indicator LED lights or flashes in blue, green, red or orange to indicate the scanner status as described below.
Lights in blue when:
• a read of a bar code is successfully complete (Note that when the auto sensing mode switching function* is enabled,
the indicator LED lights in green.),
• the "Start setting" or "End setting" bar code symbol is read from the bar-coded parameter menu (given in Chapters
13 and 14),
• bar code data read matches the master data in the data verification mode,
• the auto sensing mode switching function* has switched the scanner to the currently selected trigger switch
operating mode, or
• switched to the trigger switch operating mode using the continuous reading mode switching function.
Flashes blue when:
• the scanner, as a master, is searching for a slave device for Bluetooth
• the scanner, as a slave, is waiting for a master to initiate Bluetooth
Lights in green when:
• a processing started by magic key control has completed,
• the scanner is ready to register master data in the data verification mode,
• the scanner has read a bar code (except a master bar code for data verification) successfully with the auto sensing
mode switching function* being enabled, or
®
• the Bluetooth
wireless link is ready for use.
Lights in red when:
• a check digit error has occurred,
• a bar code read has the wrong number of digits,
• bar code data read does not match the master data in the data verification mode,
• a master bar code read has the wrong number of digits in registration of master data,
• the data retransfer function failed to transfer data,
• an editing error has occurred in the specified data editing, resulting in no transfer,
• the scanner failed to establish the Bluetooth
• pairing has failed in Bluetooth
Flashes red when:
• no master data has been registered in the data verification mode,
• the trigger switch was pressed with the "End operation" selected, or
• the trigger switch was pressed with the Bluetooth
Lights in orange when:
• the auto sensing mode switching function* has switched the scanner to the auto sensing mode, or
• switched to the continuous reading mode using the continuous reading mode switching function.
Flashes orange when:
• the charge of the battery cartridge has lowered.
*For the auto sensing mode switching function assigned to the magic key, refer to Chapter 6.
®
wireless link, or
®
authentication.
®
wireless link broken.
®
wireless connection or
®
wireless connection.