4. Inlet Filter Cap, Cleaning – Removal and Installation
The following procedure can be applied for cleaning or renewing the inlet filter cap
or inlet filter cap 'O' seals.
Warning! Before proceeding turn off the electrical and water supplies. The electricity
supply must be turned off at the mains and, if applicable, the appropriate circuit fuse
removed. Mains electrical connections are exposed when the cover is removed.
4.1 Remove the front cover, refer to
section: 'Maintenance, 3. Front Cover
– Removal and Installation'.
4.2 Unscrew the retaining screw and
remove the filter cap.
Note! A small amount of trapped
water may drain from the manifold.
4.3 Thoroughly clean both the inlet filter
meshes. Inspect the 'O' seals and
renew if required. Before refitting the
inlet filter cap lightly grease 'O' seals
with a silicone based lubricant.
4.4 Refit components in reverse order.
4.5 Restore the water supplies and check
for any leaks.
4.6 Refit the cover and secure with the
three cover retaining screws, refit the
temperature knob.
4.7 Restore the electrical supply.
4.8 Commission the shower, refer to
section: 'Commissioning.