6.
Clean the filter and non-return valve by washing them under clean
water or if damaged, replace them.
7.
Reassemble the parts in reverse order.

Thermostatic Cartridge Removal

1
Temperature Hub
Temperature
Hub Screw
Temperature Control Knob
1.
Turn off the water supply.
2.
Open the flow side of the valve to relieve any hot or cold pressure.
Note! Force will be required to pull the temperature control knob from the
Mixer.
3.
Carefully remove the temperature control knob.
4.
Unscrew the hub retaining screw and remove the temperature hub.
5.
Use a suitable wrench or spanner to unscrew and remove the cartridge
securing nut and stop block.
Caution! Risk of product damage. Make sure you protect the chrome
plated surfaces when you remove the temperature cartridge.
6.
Use a pair of grips to remove the temperature cartridge.
2
21
3
Cartridge
P4842200
1054961-W2-B