3.12 Connect the live, neutral and earth
conductors of the electrical supply
cable to the terminal block. The
supply cable earth connector should
be sleeved.
3.13 To refit the cover, replace the cover
electrical connection on the PCB by
gripping the sides of the connector
between two fingers and easing the
connector into position by moving
from side to side.
Note! Two lugs on the top of the
connector are provided to ensure the
correct orientation (see illustration).
3.14 Position the cover and secure with
the three cover retaining screws. Do
not over-tighten.
3.15 Fit the temperature control knob.
3.16 This completes the installation of
the Mira Extreme. The shower will
now require commissioning. Refer
to section: 'Commissioning'.
3.17 To install the shower fittings, refer
to your shower fittings Installation &
User Guide.