4-4-2-8. MHV (Electrification Output Enable)
Electrification Output Enable is the electrification output control signal 'PWM-LOW ACTIVE'.
When MHV-PWM LOW signal is received, Q401 turns on and the steady voltage will be accepted to the non-inverting termi-
nal of OP-AMP 324. As the voltage higher than the inverting reference voltage of OP-AMP, which is set to R405 and R406,
OP-AMP output turns high.
This output sends IB to the TRANS auxiliary wire through current-restricting resistance Q402 via R408 and C403 and Q402
turns on. When the current is accepted to Q402, Ic increases to the current proportional to time through the T401 primary coil,
and when it reaches the Hfe limit of Q402, it will not retain the "on" state, but will turn to "off". As Q402 turns 'off', TRANS N1
will have counter-electromotive force, discharge energy to the secondary unit, sends current to the load and outputs MHV volt-
age through the high voltage output enable, which is comprised of Regulation– circuit.