Maximum Page Length (MPL) ............................[c13 Max Page Length]
In DSC/DSE and LU-1 modes the Maximum Page Length value defines
the length of the page in lines. In DSC/DSE modes this value cannot be
overwritten. In LU-1 mode this defines the power on value. If set to 0 or
to a value larger than the physical page length, the maximum becomes the
default. Paper size, C01, C02 and C03 are used to determine the
maximum page length. The range is 0..999. The normal value for this field
is 66.
• 66 [0..999]
MPL
IPDS Parser syntax (with default setting):
COAX_C13 = 66;
Maximum Print Position (MPP)..............................[c14 Max Print Pos.]
In DSC/DSE and LU-1 modes the Maximum Print Position value defines
the width of the page in characters. In DSC/DSE modes this value cannot
be overwritten. In LU-1 mode this defines the power on value. If set to 0
or to a value larger than the physical page width, the maximum will be
used. Paper size, C01, C02 and C03 are used to determine the maximum
page width. The range is 0..999. The normal value for this field is 132.
• 132 [0..999]
MPP
IPDS Parser syntax (with default setting):
COAX_C14 = 132;