Interrupt Input And Quick-Response Input Detailed Settings - Omron SYSMAC CJ Series User Manual

Sysmac cj series cpu unit pulse i/o module
Hide thumbs Also See for SYSMAC CJ Series:
Table of Contents

Advertisement

2-3-1
Normal Input Operation Setting
Parameter
Input Time
• Default (8 ms)
Constant
• No filter
• 0.5 ms
• 1 ms
• 2 ms
• 4 ms
• 8 ms
• 16 ms
• 32 ms
2-3-2

Interrupt Input and Quick-response Input Detailed Settings

The following dialog box will be displayed if the Set Button in the Interrupt Inputs and Quick-response
Inputs Area of the I/O Module Tab Page in the PLC Setting Dialog Box. Items that cannot be set will be
grayed out. The items that are grayed out can be set if the required Input Operation is set.
Parameter
Input Operation
• Normal Input
• Quick-response
• Interrupt Input
Edge
• Rising Edge
• Falling Edge
Latch
• Do not Use
• Pulse Output 0
• Pulse Output 1
• Pulse Output 2
• Pulse Output 3
• High-speed
• High-speed
• High-speed
• High-speed
* Only specific pairs of interrupt inputs and pulse outputs can be used together when using interrupt
inputs with the INTERRUPT FEEDING (IFEED(892))) instruction. For details, refer to 8-4-4 INTER-
RUPT FEEDING Instruction: IFEED(892).
CJ2M CPU Unit Pulse I/O Module User's Manual
2 I/O Application Procedures and Function Allocations
Setting
Default
Default
Set the input time constant for normal
inputs IN00 to IN19.
(8 ms)
Note The input constant is ignored for
Setting
Default
Normal Input
Input
Rising Edge
Do not Use
Counter 0
Counter 1
Counter 2
Counter 3
Description
input terminals that are set for inter-
rupt inputs, quick-response inputs,
and high-speed counters.
Description
Set the function of the inter-
nal input.*
This setting is valid only
when the input is set to
Interrupt Input.
Set whether an interrupt will
occur when the input turns
ON or OFF.
This setting is valid only
when the input is set to
Interrupt Input.
Select the item to latch
when using the software
latch for the input for a
pulse output/high-speed
counter.
Related Auxiliary
Update timing in
Area words and bits
CPU Unit
---
Refreshed when
power is turned ON.
Related Auxiliary
Update timing in
Area words and bits
CPU Unit
---
Refreshed when
power is turned ON.
---
Refreshed when
operation is started.
Latched PV: A10144
Refreshed when
to A10159
power is turned ON.
2
2-9