(6) Remove 2 screws on the front side.
2
2
(7) Slide the RADF backward and take off by
lifting it up.
[B] KD-1011 (Paper Feed Pedestal (PFP))
(1) Turn OFF the power and unplug the power
cable.
(2) Take off the rear cover of the equipment.
(
Chapter 2.5.1 [C])
Note:
Disconnect the connector of the RADF first
when the RADF is installed.
(3) Remove 1 screw and the ground wire, and
then disconnect 2 connectors (3 if the op-
tional damp heater is installed).
(4) Remove 2 screws and take off 2 fixing
brackets on the rear side.
e-STUDIO350/352/353/450/452/453
OUTLINE OF THE MACHINE
2 - 42
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
05/11
Fig. 2-605
Fig. 2-606
Connector of optional
damp heater
Fig. 2-607