6.3.3 Initialization at power-ON

The carriage moves to its home position and performs the peak detection.
Then it moves to the carriage waiting position and waits.
Power-ON
Carriage home
position sensor
ON
YES
Scan motor rotating
(Moves to the forward
direction of carriage)
Carriage home
position sensor
NO
OFF
YES
Carriage home position
data set
Deceleration -> Stop
Moving peak detection
position
Peak detection
Completion of
initialization
Moving to carriage
waiting position
Scanning command
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
NO
Scan motor rotating
(Moves to backward
direction of carriage)
Carriage home
position sensor
ON
YES
Deceleration -> Stop
Fig. 6-303
6 - 7
Error handling
NO
e-STUDIO350/352/353/450/452/453