(5) Rotate the carriage-2 in the direction where
the inside of the frame is dented shown in
the figure at right, not to touch the mirror.
Then take off the carriage-2.
6
[K] Mirrors-2 and -3
(1) Take off the carriage-2 ( Chapter 6.7 [J]).
Note:
When replacing the mirrors-2 and -3, re-
place the carriage-2 together with mirrors-2
and -3.
Mirrors-2 and -3 should not be removed.
[L] Platen sensor / Carriage home position
sensor
(1) Take off the rear cover and upper rear cover
( Chapter 2.5.1 [C][G]).
(2) Disconnect 1 connector from the platen sen-
sor on the left rear position of the equipment
upper side.
(3) Release the latches of the sensor from the
frame and take off the platen sensor.
(4) Disconnect 1 connector from the carriage
home position sensor on the left rear posi-
tion of the equipment upper side.
(5) Release the latches of the sensor from the
frame and take off the carriage home posi-
tion sensor.
e-STUDIO350/352/353/450/452/453
SCANNER
Fig. 6-723
Platen sensor
Fig. 6-724
6 - 22
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
05/11
Carriage home
position sensor