(2) Incline the developer unit and discharge the
developer material from the part denoted
with the arrow.
(B-2) Filling developer unit with developer material
(1) Install the developer nozzle jig on the devel-
oper bottle.
(2) Rotate the gear on the rear side of the
developer unit to the direction of the arrow
while filling the developer unit with the de-
veloper material. Spread out the developer
material over the developer sleeve.
Note:
When installing the upper cover of developer unit,
attach the latches securely.
[C] Guide roller
(C-1) Front side
(1) Discharge the developer material
(
Chapter 12.5 (B-1)).
(2) Make a note of the position where the polar-
ity adjustment lever is pointing.
(Mark the position if needed.)
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved