Toshiba e-STUDIO453 Service Manual page 255

Hide thumbs Also See for e-STUDIO453:
Table of Contents

Advertisement

(4) Release 2 latches of the fan cover and take
off the fan cover.
(5) Release the harness from the guide of the
cover.
(6) Remove 4 screws and take off the fuser unit
cooling fan.
[C] Exit sensor
(1) Take off the fuser unit (
(2) Release 2 latches of the exit sensor cover
and take off the exit sensor cover.
(3) Release 3 latches of the exit sensor and
disconnect 1 connector while taking out
the exit sensor.
[D] Exit finger
(1) Take off the fuser unit (
(2) Open the fuser unit cover and transport
guide.
(3) Pull out the shaft from both ends of transport
guide and take off 8 exit fingers.
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Chapter 13.7 [A]).
Chapter 13.7 [A]).
13 - 17
Fig. 13-705
Fig. 13-706
Fig. 13-707
Fig. 13-708
e-STUDIO350/352/353/450/452/453
FUSER UNIT / PAPER EXIT SECTION
13