Table 6-5. Printer environmental specifications
Condition
Range
Operating
Recommended:
temperature
Minimum:
Maximum:
Humidity
Recommended:
Minimum:
Maximum:
Altitude:
Normal:
Maximum:
Heat dissipation:
DP 155 and 180
Operating:
(2-stacker
Standby:
system)
Energy Saver:
DP 100, 115,
Operating:
and 135
Standby:
(2-stacker
Energy Saver:
system)
Audible noise
Operating:
Continuous:
Impulse:
Standby:
Continuous:
Impulse:
Printer requirements and specifications
68° F to 76° F / 20° C to 24° C
50° F / 10° C
85° F / 29° C
45% ±10%
30%
65%
Up to 6,000 feet / 1,830 m
above sea level
9,000 feet / 2,743 m above
sea level
32,770 BTU/hour
4,454 BTU/hour
2,700 BTU/hour
28,140 BTU/hour
4,454 BTU/hour
2,700 BTU/hour
82 dB(A)
82 dB(A)
52 dB(A)
N/A