System Diagnostics And Testing; Base Stations Signal Checks; Handset Software Version; Battery Condition - Avaya Compact DECT Installation Manual

Table of Contents

Advertisement

Page 40 - System Diagnostics and Testing

System Diagnostics and Testing

Base Stations Signal Checks

The 20DT handsets can be used to check the signal strength and quality
being received.
1. With the handset on-hook, dial *99981* and press ENTER.
2. The handset display should be similar to that shown below.
3. Put the handset off-hook, this gives more accurate and realistic survey
4. To clear the display press < until you hear a short bleep.

Handset Software Version

The handset can provide details of its internal software version. It is unlikely
that you will need these details except if requested by the handset supplier.
1. With the handset on-hook, dial *99982* and press ENTER.
2. The handset display should be similar to that shown below.
3. To clear the display press MENU twice.

Battery Condition

The handset can display its battery charge. This appears as a set of eight
blocks across the display. Solid blocks indicate charge and empty blocks
indicate discharged. If three blocks or less appear then the handset should
be recharged.
The battery state can be checked via the MENU key options.
Page 40
Base Stations Signal Checks
RPN: 01 03
Q52: 52
RSSI: 64
– RPN is the Base Station number.
– Q52 refers to the speech quality (error rate) of the signal received
from a Base Station. Only the speech quality of the first available
base station is displayed. A value of 52 or greater is acceptable.
– RSSI refers to the signal strength from each base station. A value
of 64 or greater is acceptable.
figures.
1329 8100
SW PCS: 4
Compact DECT - Installation Manual
38DHB0002UKFH – Issue 5 (27th October 2003)