Page 32 - INDeX Integration

DECT Integration

Compact DECT Integration works with INDeX Level 8.0+. It allows 20DT
handsets (S/W PCS4E) to receive CLI or alpha tagging information from the
INDeX (overriding the name entries in the DECT database).
20DT handsets can also access the switch directory index for system speed
dials and extensions in a similar fashion to display terminals.
DECT Integration requires entry of a Mobile Numbers switch licence with
Option 1. It also requires the INDeX and Compact DECT Base Station
(CDBS) to be linked via a DECT Integration cable (see page 44).
Note: With DECT Integration operating the handsets uses directory names
All the programming shown below is performed on the INDeX switch.
A. Enable mobile numbers use with DECT integration:
B. Set the two-wire port to DECT operation:
C. Set the INDeX port speed to 19200:
D. Start the DECT Log output:
E. Ensure that the DECT directory numbers are named:
Page 32
DECT Integration
supplied by the INDeX. It is a sensible precaution to still have a User
Name, Standby Text, and Presentation Text set in the DECT handset
database.
1. From the Main Menu select System and then Switch Licences.
2. Select Mobile numbers and enter the licence key. Ensure that the
option field displays 1, indicating it is the licence for Mobile Numbers
with DECT Integration.
1. From the Main Menu select Terminal and enter the directory
number for a two-wire port connected to the DECT.
2. Select Port/Type and set this to DECT.
3. Repeat this process for all the INDeX two-wire ports connected to the
CDBS.
1. From the Main Menu select System and then Ports.
2. Press tab to select the serial port which will be connected to the
CDBS.
3. Set the ports speed to 19200.
4. Connect the integration cable between the CDBS and the INDeX
(see page 44).
1. From the Main Menu select Reports and then Start/stop Smdr,
fault, event logging and DECT.
2. Press tab to select the serial port connected to the CDBS.
3. Select Start DECT to start DECT integration. The port shows DECT
(Running) when operating correctly (you may have to leave and then
re-enter the menu).
1. Give each DECT extension number a directory name on the INDeX.