Page 24 - Using Windows CCFP Administration

Starting CCFP Admin - Direct Connection

Starting CCFP Administration
1. Ensure that the DECT system is on and that the serial cable is connected
2. Locate and click on the CCFP Administration icon.
3. A start-up display appears. The base of the display shows the current
4. The moving bar across the display allows approximately 10 seconds to
5. A configuration display momentarily appears. It will state:
6. After a caution message, the main CCFP Administration screen

Changing the Communications Configuration

1. Whilst the start-up display is shown, clicking on Change
2. Set the Com. port to match the serial port of your PC connected to your
3. Set the Connection: to the type of connection required, i.e. Direct.
4. If you wish to keep a log on communication between the CCFP and the
5. Either accept the default bit rate (19200) or change it to 9600.
6. Click on OK to return to the CCFP Administration startup display.
7. If the communication between the DECT and the PC fails, check the
Page 24
Starting CCFP Admin - Direct Connection
to it (see page 44).
Located in Start | Programs | CCFP Administration.
If you receive a message stating that communication between the CCFP
and the PC failed, then check the cabling and/or change the COM port
settings (see pages 23 and 24 respectively).
communications settings that will be used to connect with the DECT
system.
change the communication settings (see Changing the Communications
Configuration on page 24) before it attempts to make the connection with
the DECT system.
-
500 system detected
Ensure that the correct system configuration has been selected.
appears.
If the connection is okay, the screen shows handset Registration
page. The progress indicator at the top-right of the screen shows the
progress in copying down the DECT system's settings.
If the connection is not okay, the screen shows the Status page with
a sequence of ---TIMEOUT--- messages. Use File | Exit to close the
program and then check the serial port, serial cable and DECT
system.
If Error 5 appears, then another device is using the COM port.
communications configuration pauses the startup and display the
Communications Setup menu.
DECT system (for direct serial cable connection) or modem (for remote
modem connection to the DECT system).
PC, tick the Enable Log box.
cable connection (see 23).
Compact DECT - Installation Manual