• When reading the 4-bit built-in DIO port (Port 090), the decimal
value will be between 0 and 15.
• When reading an 8-bit port, the decimal value of the bits will be
between 0 and 255.
• When reading a 16-bit port, the decimal value of the 16 bits will be
between –32768 and 32767. Any time the summed decimal value of
the 16 bits would exceed +32768, the 2's complement form is used and
expressed as a negative number.
• When reading a 32-bit port, the decimal value will be between
–2147483648 and 2147483647. Any time the summed decimal value
of the 32 bits would exceed +2147483647, the 2's complement form is
used and expressed as a negative number.
DIM A$[700]
OUTPUT 709; "OLAP 1"
OUTPUT 709; "DREAD 501,100"
ENTER 709; A$
DISP A$
END
Chapter 5 Remote Interface Reference
3488 Mode Commands
! Take 100 readings.
! Enter all 100 readings.
! Display readings.