40.2.2 Remote Management Limitations
Remote management over LAN or WAN will not work when:
1. A filter in menu 3.1 (LAN) or in menu 11.5 (WAN) is applied to block a Telnet, FTP or Web
service.
2. You have disabled that service in menu 24.11.
3. The IP address in the Secured Client IP field (menu 24.11) does not match the client IP address. If
it does not match, the Prestige will disconnect the session immediately.
4. There is already another remote management session with an equal or higher priority running. You
may only have one remote management session running at one time.
5. There is a firewall rule that blocks it.

40.3 Remote Management and NAT

When NAT is enabled:
Use the Prestige's WAN IP address when configuring from the WAN.
Use the Prestige's LAN IP address when configuring from the LAN.

40.4 System Timeout

There is a default system management idle timeout of five minutes (three hundred seconds). The Prestige
automatically logs you out if the management session remains idle for longer than this timeout period. The
management session does not time out when a statistics screen is polling or when sys stdio has been
changed on the command line.
Remote Management
Prestige 652H/HW Series User's Guide
40-3