Prestige 652H/HW Series User's Guide
35.4 SNMP Traps
The Prestige will send traps to the SNMP manager when any one of the following events occurs:
TRAP #
1
coldStart (defined in RFC-1215)
2
warmStart (defined in RFC-1215)
3
linkDown (defined in RFC-1215)
4
linkUp (defined in RFC-1215)
5
authenticationFailure (defined in
RFC-1215)
6
whyReboot (defined in ZYXEL-
MIB)
6a
For intentional reboot :
The port number is its interface index under the interface group.
35-4
Table 35-2 SNMP Traps
TRAP NAME
Table 35-3 Ports and Permanent Virtual Circuits
PORT
PVC (PERMANENT VIRTUAL CIRCUIT)
1
Ethernet LAN
2
1
3
2
...
...
13
12
14
xDSL
A trap is sent after booting (power on).
A trap is sent after booting (software reboot).
A trap is sent with the port number when any of the links
are down. See the following table.
A trap is sent with the port number.
A trap is sent to the manager when receiving any SNMP
gets or sets requirements with wrong community
(password).
A trap is sent with the reason of restart before rebooting
when the system is going to restart (warm start).
A trap is sent with the message "System reboot by user!" if
reboot is done intentionally, (for example, download new
files, CI command "sys reboot", etc.).
DESCRIPTION
SNMP Configuration