Options - Icom IC-V80 Instruction Manual

Vhf/uhf transceivers
Hide thumbs Also See for IC-V80:
Table of Contents

Advertisement

Previous view
14

OPTIONS

■ VOX function (Continued)
D VOX-related settings
The VOX gain, VOX delay, and VOX time-out timer is set
in the Set mode.
q Connect an optional headset and plug adapter cable
to the transceiver, and then turn ON the power.
w Push [FUNC](M), and then push [VOX](2) to turn ON
the VOX function.
e Push [FUNC](M), and then push [SET](8) to enter the
Set mode.
r Push [Y] or [Z] to select the VOX gain (VOX), VOX
delay (VXd), or VOX time-out timer (Vto) item.
t Rotate [VOL] to select a option.
y Push [# ENT] to exit the Set mode.
The VOX function is not activated while in the Set
mode.
• VOX gain
The VOX gain level can be adjusted between 1 (minimum)
and 10 (maximum), or turned OFF. Higher values make
the VOX function more sensitive to your voice.
➥ While speaking into the headset microphone, adjust
the VOX gain until "On" continuously appears on the
display.
If "On" is intermittent, be sure the VOX delay is set
long enough to allow normal pauses in speech, but
keep the VOX ON until you fi nish speaking.
✔ CONVENIENT!
While transmitting using the VOX function, you can ad-
just the VOX gain simply by rotating [VOL].
• VOX delay
Set the VOX delay to between 0.5 and 3.0 seconds (in
0.5 seconds steps). The VOX delay is the amount of
time the transmitter stays ON after you stop speaking.
(default: VXd.10)
• VOX time-out timer
Set the VOX time-out timer to between 1, 2, 3 (default),
4, 5, 10 and 15 minutes to prevent accidental prolonged
transmission for the VOX function.
To turn OFF the function, select "Vto.OF."
The VOX time-out timer must be set shorter than the
time-out timer, otherwise this timer will not function.
Push
• The "VOX gain" item in the Set mode
(default: VOX.05)
The VOX function is turned OFF.
• The "VOX delay" item in the Set mode
The VOX delay is set to 1 second.
• The "VOX time-out timer" item in the Set mode
The VOX time-out timer is
set to 3 minutes. (default)
50
, and then push
.
A
The VOX gain is set to 10 (max.)
Appears
The VOX delay is set to 3 seconds.
VOX time-out timer is
set to 15 minutes (maximum).

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic-v80eIc-u80Ic-u80e

Table of Contents