WEB OPERATION
Please refer to the following chart for detailed information:
Parameter Function
Event
Type
Channel
Enable
Sensitivity
Region
Period
Anti-dither
Normal
out
Alarm
latch
Alarm
upload
Record
channel
Record
latch
Email
There are three types: Motion detection/video loss/Camera Masking.
Select channel name from the dropdown list.
You need to put a checkmark to enable motion detection function.
There are six levels. The sixth level has the highest sensitivity.
Region: If you select motion detection type, you can click this button
to set motion detection zone. The interface is shown in
There are PAL 22X18/NTSC 22X15 zones. Right click mouse you can
go to full-screen display mode. Click OK button to save your motion
detection zone setup.
Motion detection function becomes activated in the specified periods.
There are six periods in one day. Put a checkmark to enable
corresponding period.
Select date. If you do not select, current setup applies to today only.
You can select all week column to apply to the whole week.
Click OK button, system goes back to motion detection interface;
please click save button to exit.
System only memorizes one event during the anti-dither period. The
value ranges from 0s to 15s.
There is 2-channel alarm output.
Corresponding to motion detection alarm output port (multiple
choices)
Enable alarm activation function. You need to select alarm output port
so that system can activate corresponding alarm device when alarm
occurs.
System can delay the alarm output for specified time after alarm ends.
The value ranges from 10s to 300s.
System can upload the alarm signal to the centre (Including alarm
centre.
System auto activates motion detection channel (multiple choices) to
record once alarm occurs (working with motion detection function).
Please note current device shall be in alarm record period (Chapter
7.3.2.3 Schedule) and you have enabled the schedule record function
in chapter 7.3.3.3 Record.
System can delay the record for specified time after alarm ends. The
value ranges from 10s to 300s.
If you enabled this function, System can send out an email to alert you
when alarm occurs and ends.