Instruction Manual
3.
Turn the instrument over and remove screw from battery cover as shown
in Figure 2-1.
4.
Use your thumbs to push off the battery cover as shown in Figure 2-1.
5.
Slide the battery out of the compartment as shown in Figure 2-2.
6.
Carefully pull the battery clip free from the battery terminals (if
replacing the battery) and attach the new battery.
7.
Slide the battery and its leads into the compartment and slide the cover
into place.
Figure 2-1. Removal of Battery Compartment Cover
2-4
Use thumbs to push
battery cover down
and then out from
instrument case.
Figure 2-2. Battery Removal and Fuses