Fluke 80 Series V Getting Started Manual

80 series v multimeters
Hide thumbs Also See for 80 Series V:

Advertisement

Quick Links

®
80 Series V
Multimeters
Getting Started Manual
PN 2101973
May 2004 Rev.2, 11/08
©
2004, 2008 Fluke Corporation. All rights reserved. Printed in U.S.A.
Specifications are subject to change without notice.
All product names are trademarks of their respective companies.

Advertisement

Table of Contents
loading

Summary of Contents for Fluke 80 Series V

  • Page 1 80 Series V Multimeters Getting Started Manual PN 2101973 May 2004 Rev.2, 11/08 © 2004, 2008 Fluke Corporation. All rights reserved. Printed in U.S.A. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
  • Page 2 This warranty covers the original purchaser only and is not transferable. For ten years from the date of purchase, this warranty also covers the LCD. Thereafter, for the lifetime of the DMM, Fluke will replace the LCD for a fee based on then current component acquisition costs.
  • Page 3: Table Of Contents

    Table of Contents Title Page Introduction........................1 Contacting Fluke ......................1 Safety Information ......................1 The Meter's Features ..................... 4 Power-Up Options ..................... 11 Automatic Power-Off ....................11 Input Alert™ Feature ....................11 Low Pass Filter (87)....................11 Bar Graph........................12 ®...
  • Page 4 80 Series V Getting Started Manual...
  • Page 5 List of Tables Table Title Page Electrical Symbols ......................... 3 Inputs............................. 4 Rotary Switch Positions......................5 Pushbuttons .......................... 6 Display Features........................9 MIN MAX Functions....................... 12 Model 87 AC Voltage Function Specifications ............... 15 Model 83 AC Voltage Function Specifications ............... 16 DC Voltage, Resistance, and Conductance Function Specifications ........
  • Page 6 80 Series V Getting Started Manual...
  • Page 7: Introduction

    Use this Meter only as specified in this manual or the protection provided by the Meter might be impaired. To contact Fluke, call one of the following telephone numbers: Do not use the Meter if it is damaged. Before you use USA: 1-888-44-FLUKE (1-888-443-5853) the Meter, inspect the case.
  • Page 8 80 Series V Getting Started Manual Never operate the Meter with the cover removed or the When using probes, keep fingers behind the case open. finger guards on the probes. Use caution when working with voltages above 30 V Do not use the Low Pass Filter option to verify the ac rms, 42 V ac peak, or 60 V dc.
  • Page 9: Electrical Symbols

    Multimeters Safety Information Table 1. Electrical Symbols AC (Alternating Current) Earth ground DC (Direct Current) Fuse Hazardous voltage Conforms to European Union directives. Risk of Danger. Important information. See Manual. Conforms to relevant Canadian Standards Association directives. Battery. Low battery when displayed. Double insulated Continuity test or continuity beeper tone.
  • Page 10: The Meter's Features

    80 Series V Getting Started Manual The Meter's Features Tables 2 through 5 briefly describe the Meter's features. Table 2. Inputs Terminal Description Input for 0 A to 10.00 A current (20 A overload for 30 seconds maximum), current frequency, and duty cycle measurements.
  • Page 11: Rotary Switch Positions

    Multimeters The Meter's Features Table 3. Rotary Switch Positions Switch Position Function Any Position When the Meter is turned on, the Meter model number briefly appears on the display. AC voltage measurement Press for low pass filter (K) (87 only). DC voltage measurement 600 mV dc voltage range Press...
  • Page 12: Pushbuttons

    Enables the Meter’s calibration mode and prompts for a password. The Meter reads “ “ and enters calibration mode. See the 80 Series V Service Information Any switch Switches between the ranges available for the selected function. To return to autoranging, hold the button down for 1 position second.
  • Page 13 Multimeters The Meter's Features Table 4. Pushbuttons (cont.) Switch Button Function Position Any switch AutoHOLD (formerly TouchHold) captures the present reading on the display. When a new, stable reading is detected, the position Meter beeps and displays the new reading. MIN MAX Stops and starts recording without erasing recorded values.
  • Page 14 (Relative mode) Power-up Enables zoom mode for the bar graph. Refer to Zoom Mode in the Users Manual located on the 80 Series V User 2rEL Manuals CD. The Meter reads “ ” until is released.
  • Page 15: Display Features

    Multimeters The Meter's Features Indication Number Feature Indicates negative readings. In relative mode, this sign indicates that the present input is less than the stored reference. Indicates the presence of a high voltage input. Appears if the input voltage is 30 V or greater (ac or dc).
  • Page 16 For more information, See “Bar Graph” in the Users Percent. Used for duty cycle Manual located on the 80 Series V User Manual CD. The bar graph also has a measurements. zoom function, as described under "Zoom Mode".
  • Page 17: Power-Up Options

    Multimeters The Meter's Features Low Pass Filter (87) Power-Up Options The 87 is equipped with an ac low pass filter. When measuring ac voltage Holding a button down while turning the Meter on activates a power-up or ac frequency, press A to activate the low pass filter mode (K). option.
  • Page 18: Bar Graph

    The graph is not shown for capacitance, frequency The bar graph also has a zoom function, as described under “Zoom counter functions, temperature, or peak min max. Mode” in the Users Manual located on the 80 Series V User Manuals CD. Table 6. MIN MAX Functions Button MIN MAX Function Enter MIN MAX recording mode.
  • Page 19: Autohold Mode

    To prevent damage or injury, install ONLY specified replacement fuses with the amperage, voltage, and speed ratings shown in Replacement Parts in the Users Manual located on the 80 Series V User Manual CD.
  • Page 20: Specifications

    80 Series V Getting Started Manual Specifications Maximum Voltage between any Terminal and Earth Ground: 1000 V rms W Fuse Protection for mA or A inputs: 44/100 A, 1000 V FAST Fuse W Fuse Protection for A input: 11 A, 1000 V FAST Fuse Display: Digital: 6000 counts updates 4/sec;...
  • Page 21: Detailed Specifications

    Multimeters Specifications Detailed Specifications For all detailed specifications: Accuracy is given as ([% of reading] + [number of least significant digits]) at 18° C to 28° C, with relative humidity up to 90 %, for a period of one year after calibration.
  • Page 22: Model 83 Ac Voltage Function Specifications

    80 Series V Getting Started Manual Table 8. Model 83 AC Voltage Function Specifications Function Range Resolution Accuracy 50 Hz - 60 Hz 30 Hz - 1 kHz 1 kHz - 5 kHz 600.0 mV 0.1 mV (0.5 % + 4) (1.0 % + 4)
  • Page 23: Dc Voltage, Resistance, And Conductance Function Specifications

    Multimeters Specifications Table 9. DC Voltage, Resistance, and Conductance Function Specifications Accuracy Function Range Resolution Model 83 Model 87 6.000 V 0.001 V (0.1 % + 1) (0.05 % + 1) 60.00 V 0.01 V (0.1 % + 1) (0.05 % + 1) 600.0 V 0.1 V (0.1 % + 1)
  • Page 24: Current Function Specifications

    80 Series V Getting Started Manual Table 11. Current Function Specifications Accuracy Burden Voltage Function Range Resolution 2, 3 (typical) Model 83 Model 87 60.00 mA 0.01 mA (1.2 % + 2) (1.0 % + 2) 1.8 mV/mA 400.0 mA 0.1 mA...
  • Page 25: Capacitance And Diode Function Specifications

    Multimeters Specifications Table 12. Capacitance and Diode Function Specifications Function Range Resolution Accuracy 10.00 nF 0.01 nF (1 % + 2) 100.0 nF 0. 1 nF (1 % + 2) 1.000 F 0.001 F (1 % + 2) 10.00 F 0.01 F (1 % + 2) 100.0 F...
  • Page 26: Frequency Counter Sensitivity And Trigger Levels

    80 Series V Getting Started Manual Table 14. Frequency Counter Sensitivity and Trigger Levels Minimum Sensitivity (RMS Sine wave) Approximate Trigger Level Input Range 5 Hz - 20 kHz 0.5 Hz - 200 kHz (DC Voltage Function) 600 mV dc...
  • Page 27: Electrical Characteristics Of The Terminals

    Multimeters Specifications Table 15. Electrical Characteristics of the Terminals Input Common Mode Overload Impedance Rejection Ratio Normal Mode Rejection Function Protection (nominal) (1 k unbalance) 1000 V rms 10 M < 100 pF > 120 dB at dc, 50 Hz or 60 Hz >...