Operation
USmNG
THE
GENERATOR
System
Ground
The generator has a system ground that connects the
generator
frame
components
to the ground
terminals
on
the AC output
receptacles.The
system
ground
is connected
to the AC neutral
wire
(see "Equipment
Description",
earlier
in this manual).
Special
Requirements
There
may be Federal or State Occupational
Safety and
Health Administration
(OSHA)
regulations,
local codes, or
ordinances
that apply to the intended
use of the generator.
Please consult
a qualified electrician,
electrical
inspector,
or
the local agency having jurisdiction.
" In some areas, generators
are required
to be registered
with local utility companies.
° If the generator
is used at a construction
site, there
may
be additional
regulations
which must be observed.
Connecting
to a Building's
Electrical
System
Connections
for
standby
power
to a building's
electrical
system
must
be made
by a qualified
electrician.The
connection
must
isolate
the
generator
power
from
utility
power,
and
must
comply
with
all applicable
laws
and
electrical
codes.
When
using generator
for backup power, notify utility
company.
Use approved
transfer
equipment
to isolate
generator
from
electric
utility.
* Use a ground
fault circuit
interrupter
(GFC[)
in any damp
or
highly conductive
area_ such as metal
decking
or steel work:
. DO NC)T touch
bare wires
or receptacles.
. DO NOT
use generator
with electrical
cords
which are worn,
frayed,
bare or otherwise
damaged.
DO NOT
operate
generator
in the rain.
. DO NOT
handle generator
or electrical
cords
while standing
in water, while barefoot,
or while
hands or feet are wet.
. DO NOT
allow unqualified
persons
or children
to operate
or
service
generato_i
Generator
Location
Generator
Cmearance
Operate
generator
ONLY outdoors.
Keep exhaust
gas from
entering
a confined
area through
windows,
doors,
ventilation
intakes
or other
openings.
DO NOT operate
generator
inside any building or enctosure_
including the generator
compartment
of a recreational
vehicle (RV).
The
generator
must
be at least
5 ft. (I 52 cm) from
structures
having
combustible
walls
and/or
other
combustible
materials.
Leave
at least
3 ft. (92 cm) all around
generator
including
overhead,
for adequate
cooling,
maintenance
and
servicing.
Place
generator
in a well
ventilated
area,
which
will allow
for
removal
of deadly
exhaust
gas. DO
NOT
place
generator
where
exhaust
gas could
accumulate
and
enter
inside
or be drawn
into
a potentially
occupied
building.
Ensure
exhaust
gas is kept
away
from
any windows,
doors,
ventilation
intakes
or other
openings
that
can allow
exhaust
gas to collect
in a confined
area
(Figure
4). Prevailing
winds
and
air currents
should
be taken
into
consideration
when
positioning
generaton
Exhaust
Port
\
O