Troy-Bilt 1925 Owner's Manual
Hide thumbs Also See for 1925:
Table of Contents

Advertisement

Available languages

Available languages

Owner's Manual / Manual del Propietario
Portable Generator / Generador Portátil
Model / Modelo 01925
IMPORTANT: READ SAFETY RULES AND INSTRUCTIONS CAREFULLY
IMPORTANTE: LEYO LA SEGURIDAD LAS ORDENES Y LAS INSTRUCCIONES DETENIDAMENTE
Questions? Preguntas?
Helpline - 1-888-611-6708 M-F 8-5 CT
Troy-Bilt® is a registered trademark of Troy-Bilt, LLC and is used under license to Briggs & Stratton Power Products.
Troy-Bilt® es una marca registrada de Troy-Bilt, LLC y se usa abajo licencia a Briggs & Stratton Power Products.
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
JEFFERSON,WISCONSIN, U.S.A.
Printed in USA
Manual No. 192472GS Revision 6 (03/23/2004)

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Troy-Bilt 1925

  • Page 1 Helpline - 1-888-611-6708 M-F 8-5 CT Troy-Bilt® is a registered trademark of Troy-Bilt, LLC and is used under license to Briggs & Stratton Power Products. Troy-Bilt® es una marca registrada de Troy-Bilt, LLC y se usa abajo licencia a Briggs & Stratton Power Products.
  • Page 2: Table Of Contents

    Section Safety Rules TABLE OF CONTENTS SAFETY RULES Safety Rules........2-4 This is the safety alert symbol.
  • Page 3: Safety Rules

    Section 1: Safety Rules DANGER WARNING Running generator gives off carbon monoxide, Fuel and its vapors are extremely flammable and an odorless, colorless, poison gas. explosive. Breathing carbon monoxide will cause nausea, Fire or explosion can cause severe burns or fainting or death.
  • Page 4 Section 1: Safety Rules CAUTION WARNING Exceeding generator’s wattage/amperage capacity can damage generator and/or electrical devices connected Unintentional sparking can result in fire or to it. electric shock. • See “Don’t Overload Generator” on page 13. • Start generator and let engine stabilize before connecting WHEN ADJUSTING OR MAKING REPAIRS TO YOUR electrical loads.
  • Page 5: Know Your Generator

    Features and Controls Section KNOW YOUR GENERATOR Read this owner’s manual and safety rules before operating your generator. Compare this illustration with your generator to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. Rocker Switch Circuit Oil Fill Cap Fuel Tank...
  • Page 6: Assembly

    Assembly Section ASSEMBLY To install: Cut off tie wrap securing loose end of negative (black) Your generator requires attachment of the negative battery cable. cable and is ready for use after it has been properly Attach negative battery cable with 5/16” x 3/4” screw serviced with the recommended oil and fuel.
  • Page 7 Section 3: Assembly Attach Handle BEFORE STARTING THE You will need two 1/2” or 13 mm wrenches to attach the ENGINE handle. Attach handle to right side of generator frame (viewing Add Engine Oil and Fuel unit from front), as shown in Figure 2, with a 60 mm capscrew, flat washers, nylon washers, and lock nut.
  • Page 8 Operation Section USING THE GENERATOR OPERATING THE GENERATOR System Ground CAUTION The generator has a system ground that connects the generator frame components to the ground terminals on Exceeding generator’s wattage/amperage capacity can the AC output receptacles.The system ground is connected damage generator and/or electrical devices connected to the AC neutral wire (see “Equipment Description”, to it.
  • Page 9: Connecting Electrical Loads

    Section 4: Operation Jump Start Procedure Connect the other RED jumper cable clamp to the starting battery’s POSITIVE battery terminal. If the generator’s starting battery fails, use the following Connect the BLACK jumper cable clamp to the instructions to jump start your generator.You can jump starting battery’s NEGATIVE battery terminal.
  • Page 10 Section 4: Operation Charging a Battery Connect battery charge cable clamp with black handle to the negative (–) battery terminal (Figure 6). Your generator has the capability of recharging a discharged Start engine. Let engine run while battery recharges. 12 Volt automotive or utility style storage battery. DO NOT use the unit to charge any 6 Volt batteries.
  • Page 11: Operation

    Section 4: Operation COLD WEATHER GENERATOR ADAPTER OPERATION CORD SET Under certain weather conditions (temperatures below The generator is equipped with a 25’ generator adapter cord 40°F [4°C] and a high dew point), your generator may set designed for a 240 Volt, 30 Amp grounded neutral circuit experience icing of the carburetor and/or the crankcase (Figure 9).The generator adapter cord set provides a breather system.
  • Page 12 Section 4: Operation RECEPTACLES Use each receptacle to operate 120 Volt AC, single–phase, 60 Hz electrical loads requiring up to 2,400 watts (2.4 kW) CAUTION at 20 Amps of current. Use cord sets that are rated for 125 Volt AC loads at 20 Amps (or greater). Receptacles may be marked with rating value greater than generator output capacity.
  • Page 13: Power Management

    Section 4: Operation DON'T OVERLOAD Plug in and turn on the next load. Again, permit the generator to stabilize. GENERATOR Repeat steps 4 and 5 for each additional load. NEVER add more loads than the generator capacity.Take special care to consider surge loads in generator capacity, Capacity as described above.
  • Page 14: Maintenance

    Maintenance Section GENERAL MAINTENANCE After oil has drained, reinstall the oil drain plug. Remove the oil drain tray from under the oil drain plug RECOMMENDATIONS and clean up any spilled oil. Changing Oil Filter The Owner/Operator is responsible for making sure that Place the half moon notch in the oil drain tray under all periodic maintenance tasks are completed on a timely the oil filter (Figure 15).
  • Page 15: Generator Maintenance

    Section 5: Maintenance Generator Maintenance Data Tag Generator maintenance consists of keeping the unit clean Data tag information is very important if you need help and dry. Operate and store the unit in a clean dry from our Customer Service Department or an authorized environment where it will not be exposed to excessive service dealer.
  • Page 16: Storage

    Section Storage STORAGE Engine Storage See engine owner’s manual for instructions. The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot Other Storage Tips be done and you must store the unit for more than •...
  • Page 17: Troubleshooting

    Troubleshooting Section TROUBLESHOOTING Problem Cause Correction One of the circuit breakers is Reset circuit breaker. open. Fault in generator. Contact Authorized service facility. No AC output is available, but Poor connection or defective Check and repair. generator is running. cord set. Connected device is bad.
  • Page 18 Wiring Diagram and Schematic Section SCHEMATIC...
  • Page 19: Schematic/Wiring Diagram

    Section 8: Wiring Diagram and Schematic WIRING DIAGRAM...
  • Page 20 Exploded Views and Parts Lists Section EXPLODED VIEW - MAIN UNIT...
  • Page 21 Section 9: Exploded Views and Parts Lists PARTS LIST - MAIN UNIT Item Part # Description Item Part # Description B191821GS CRADLE 45 49820GS NUT, Nylok B193086GS CRADLE,Top 46 22145GS WASHER ASSY, DC Control Panel (see page 23) 47 51730GS SCREW 193263GS SCREW...
  • Page 22 Section 9: Exploded Views and Parts Lists AC CONTROL PANEL EXPLODED VIEW & PARTS LIST Item Part # Description 188914GS COVER, Lid, Control Panel 192273BGS CONTROL PANEL, Compact 189167GS CLIP, Hinge Pin Retainer 189182GS SPRING, Hinge, Pin 189166GS PIN, Hinge, Cover, Compact 68759GS OUTLET, 120V, 20A, Duplex 189165GS...
  • Page 23 Section 9: Exploded Views and Parts Lists DC CONTROL PANEL EXPLODED VIEW & PARTS LIST Item Part # Description 192367GS PANEL, DC Control 194838GS KIT, SRS, Switch with Knob 194840GS ASSY, Jack, Coaxial with Cap 194839GS KIT, Circuit Breaker 90418GS OUTLET, 12VDC, Snap...
  • Page 24 Section 9: Exploded Views and Parts Lists ALTERNATOR EXPLODED VIEW & PARTS LIST Item Part # Description 186059GS ADAPTER, Mounting, Alternator 192171GS ROTOR 192186AGS STATOR 193336GS RBC, (with O-Ring p/n 189197GS) 86308KGS SCREW 66386GS ASSY, Holder, Brush 66849GS SCREW 22694GS RECEPTACLE, 6 pin 81917GS PIN, Roll...
  • Page 25: Notes

    Notes NOTES...
  • Page 26 Sección Reglas de Seguridad TABLA DE CONTENIDOS REGLAS DE SEGURIDAD Reglas De Seguridad ....... . 26-28 Éste es el símbolo de alerta de seguridad.
  • Page 27: Reglas De Seguridad

    Sección 1: Reglas de Seguridad PELIGRO ADVERTENCIA Al generador funcionar, se produce monóxido de La gasolina y sus vapores son extremadamente carbono, un gas inodoro y venenoso. inflamables y explosivos. El respirar el monóxido de carbono, producirá El fuego o una explosión pueden causar quemaduras náusea, desmayo o la muerte.
  • Page 28 Sección 1: Instrucciones de Seguridad PRECAUCIÓN ADVERTENCIA El sobrepasar la capacidad del amperaje y vataje del generador, puede dañar al generador y los aparatos eléctricos Chispear involuntario puede tener como resultado el conectados al mismo. fuego o el golpe eléctrico. •...
  • Page 29: Conozca Su Generador

    Sección Características y Mandos CONOZCA SU GENERADOR LEA ESTE MANUAL DEL PROPIETARIO Y LAS REGLAS DE SEGURIDAD ANTES DE OPERAR SU GENERADOR. Compare las ilustraciones con su Generador para familiarizarse con las ubicaciones de los diferentes controles y ajustes. Conserve este manual para referencias futuras.
  • Page 30 Sección Montaje MONTAJE Para instalar: Corte el cablecito que está aguantando el cable negro, para Su generador requiere de ciertos procedimientos de montaje y poderlo usar. solo estará listo para ser utilizado después de haberle Fije el cable negativo de la batería con el 5/16” x 3/4” tornillo suministrado servicio con el combustible y aceite recomendados.
  • Page 31 Sección 3: Montaje Fije el Asa ANTES DE DARLE ARRANQUE AL Necesitará dos llaves inglesas de 13 mm o 1/2” para fijar el asa. MOTOR Fije el asa al lateral derecho del bastidor del generador (visto desde la parte delantera de la unidad), como se muestra en la Agregar Aceite al Motor y Combustible Figura 18.
  • Page 32: Tierra Del Sistema

    Sección Operación USO DEL GENERADOR OPERANDO EL GENERADOR PRECAUCIÓN Tierra del Sistema El sobrepasar la capacidad del amperaje y vataje del El generador dispone de una conexión a tierra del sistema que generador, puede dañar al generador y los aparatos eléctricos conecta los componentes del bastidor a los terminales de tierra conectados al mismo.
  • Page 33: Parado Del Motor

    Sección 4: Operación Procedimiento de Arranque en Puente Conecte la otra pinza del cable de puente ROJO al terminal POSITIVO de la batería de arranque. Si falla la batería de arranque del generador, siga estas Conecte la otra pinza del cable de puente NEGRO al instrucciones para arrancarlo en puente.
  • Page 34: Carga De La Bateria

    Sección 4: Operación Carga de la Bateria Conecte el sujetador del cable de carga de la batería que tiene la manija negra al terminal negativo (-) de la batería Su generador tiene la capacidad de recargar baterías descargadas (Figura 22). de acumuladores tipo servicio o automotriz de 12 Voltios.
  • Page 35 Sección 4: Operación OPERACIÓN DURANTE UN Asegúrese que existe un espacio mínimo de dos pies entre el lado abierto de la caja y el objeto más cercano. CLIMA FRÍO Coloque la parte abierta fuera del viento y otros elementos. Bajo ciertas condiciones ambientales (temperaturas por debajo de La cobertura debería aguantar el calor suficiente creado por los 40ºF [4ºC] y un punto alto Dew), su generador puede el generador para prevenir problemas.
  • Page 36 Sección 4: Operación JUEGO DE CABLES DEL RECEPTÁCULOS ADAPTADOR DEL GENERADOR Tomacorrientes de 12 Voltios DC El generador está equipado con un Juego de Cables del Adaptador Este tomacorriente le permite recargar una batería de del Generador de 25 pies, diseñado para un circuito neutro a almacenamiento tipo servicio o automotriz de 12 Voltios tierra de 240 voltios, 30 Amperios (Figura 25).
  • Page 37 Sección 4: Operación 120 Volt AC, 20 Amp, Receptáculos Dobles 120/240 Voltios AC, 30 Amp, Receptáculo de Seguridad Cada receptáculo (Figura 27) está protegido en contra de sobrecargas por un corto-circuitos de, del tipo "empuje para Use un tapón NEMA L14-30 con este receptáculo. Conecte un reposicionar".
  • Page 38 Sección 4: Operación NO SOBRECARGUE EL Conecte y encienda la próxima carga. De nuevo, permita que el generador se estabilice. GENERADOR Repita los pasos 4 y 5 para cada carga adicional que usted tenga. Capacidad NUNCA añada más cargas sobre la capacidad del generador. Usted debe asegurarse que su generador puede proveer el Tome una atención especial en considerar las cargas de corriente suficiente vataje calificado (cuando esté...
  • Page 39: Mantenimiento

    Sección Mantenimiento RECOMENDACIONES Una vez vaciado el aceite, vuelva a colocar el tapón de vaciado de aceite. GENERALES DE Retire la bandeja de vaciado de aceite de debajo del tapón y MANTENIMIENTO limpie los restos de aceite. Cambio del Filtro de Aceite El propietario / operador es responsable por asegurarse de que todos los trabajos periódicos de mantenimiento se lleven a cabo Sitúe la muesca en forma de media luna de la bandeja de...
  • Page 40: Mantenimiento Del Generador

    Sección 5: Mantenimiento Mantenimiento del Generador Placa de Características Localice la placa de características del generador y copie la El mantenimiento del generador consiste en conservar la unidad información en el espacio disponible a continuación. Esta limpia y seca. Opere y almacene la unidad en un ambiente limpio y información es fundamental para poder recibir ayuda de nuestro seco donde no será...
  • Page 41: Almacenamiento

    Sección Almacenamiento ALMACENAMIENTO Almacenando el Motor Consulte el manual del propietario del motor para las El generador deberá ser encendido al menos una vez cada siete instrucciones de cómo preparar adecuadamente el motor para su días y deberá dejarlo funcionar al menos durante 30 minutos. Si almacenamiento.
  • Page 42: Diagnosticos De Averías

    Sección Diagnosticos de Averías DIAGNOSITICOS DE AVERÍAS Problemo Causa Accion El interruptor automático de circuito Reposicione el interruptor. está abierto. Conexión mal o defectuosa del juego Revise y repare. El motor está funcionando pero no de cables. existe salida de AC disponsible. El dispositivo conectado está...
  • Page 43 GARANTÍA LIMITADA "Troy-Bilt® es una marca registrada de Troy-Bilt, LLC bajo licencia de Briggs & Stratton Power Products. Briggs & Stratton Power Products reparará o sustituirá sin cargo alguno cualquier componente del equipo** que presente defectos de materiales y/o mano de obra. Los gastos de transporte de las piezas enviadas para reparar o sustituir conforme a los términos de esta garantía correrán a cargo del comprador.
  • Page 44 LIMITED WARRANTY “Troy-Bilt® is a registered trademark of Troy-Bilt, LLC and is used under license to Briggs & Stratton Power Products. Briggs & Stratton Power Products will repair or replace, free of charge, any part, or parts of the equipment** that are defective in material or workmanship or both.Transportation charges on parts submitted for repair or replacement under this warranty must be...

Table of Contents