Troy-Bilt 1923 Owner's Manual
Hide thumbs Also See for 1923:

Advertisement

Available languages

Available languages

Quick Links

O
m
m
IWm
Owner's Manual / Manual del Propietario
Portable
Generator
/ Generador
Port_til
Model / Modelo 01923
®
IMPORTANT:
READ SAFETY
RULES
AND
INSTRUCTIONS
CAREFULLY
IMPORTANTE:
LEYO
LA SEGURIDAD
LAS ORDENES
Y LAS INSTRUCCIONES
DETENIDAMENTE
Questions? Preguntas?
Helpline
- 1-888-611-6708
M-F 8-5 CT
Troy-Bilt@ is a registered trademark of MTD and is used under licenseto Briggs & Stratton Power Products.
Troy-Bilt_ es una marca registrada registrada de MTD y se usa abajo licencia a Briggs& Stratton Power Products.
BRIGGS
& STRATTON
POWER
PRODUCTS
GROUP,
LLC
JEFFERSON,
WISCONSIN,
U.S.A.
Printed in USA
Manual No. 192411GS Revision I (02/05/2003)

Advertisement

Table of Contents
loading

Summary of Contents for Troy-Bilt 1923

  • Page 1 - 1-888-611-6708 M-F 8-5 CT Troy-Bilt@ is a registered trademark of MTD and is used under licenseto Briggs & Stratton Power Products. Troy-Bilt_ es una marca registrada registrada de MTD y se usa abajo licencia a Briggs& Stratton Power Products.
  • Page 2: Table Of Contents

    Safety Rules TABLE OF CONTENTS SAFETY RULES Safety Rules........Know Your Generator ......This is the safety alert symbol. It is used to alert you to potential personal injury Assembly........hazards. Obey all safety messages that follow Operation ........8- I0 this symbol to avoid possible injury or death.
  • Page 3: Safety Rules

    Section 1: Safety Rules DANGER WARNING Operate generator ONLY outdoors. WHEN ADDING FUEL Keep at least 2 feet of clearance on all sides of generator for Turn generator OFF and let it cool at least 2 minutes before adequate ventilation. removing gas cap.
  • Page 4 Section 1: Safety Rules CAUTION WARNING See "Don't Overload Generator" on page 10. Start generator and let engine stabilize before connecting electrical loads. ;ENERATOR Connect electrical loads in OFF position, then turn ON for Disconnect the spark plug wire from the spark plug and place operation.
  • Page 5: Know Your Generator

    Features and Controls KNOW YOUR GENERATOR Read this owner's manual and safety rules before operating your generator. Compare the illustrations with your generator to familiarize yourself with the locationsof various controls and adjustments. Savethis manual for future reference. Spark Plug (inside FuelTank cover) Engine ON/OFF Switch...
  • Page 6: Assembly

    ASSEMBLY • If the oil level is not at the point of overflowing from the oil filler neck, slowly fill engine with recommended oil. • Reinstall oil filler cap and tighten securely. Carton Contents • Replacethe oil fill cover. Check all contents. If any parts are missing or damaged,call •...
  • Page 7: Operation

    Operation GROUNDING • Be sure the spark plug wire is attached to the spark plug. • Turn the fuel valve to the "Open" position (fully G EN ERATO R clockwise) (Figure 4). The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground.
  • Page 8 Section 4: Operation NOTE: If engine starts after 3 pulls, but fails to run for Oil Alert System more than l0 seconds, check for proper oil level in The Oil Alert System is designedto prevent engine damage crankcase. This unit is equipped with a Oil Alert System caused by an insufficient amount of oil in the crankcase.
  • Page 9 Section 4: Operation AUTION! Although each receptacle is rated for 120 Volts at 15 Amps (I,440 watts or 1.44kW), the generator is rated for a total of 1,000watts. To 12 Volt DC Panel Powering loads that exceed the wattage capacity of Receptacle the generator can damage it or cause serious Red Lead...
  • Page 10 Section 4: Operation DON'T OVERLOAD Plug in and turn on the next load. Again, permit the generator to stabilize. G EN ERATO R Repeat steps 4 and 5 for each additional load. NEVER add more loadsthan the generator capacity. Take special care to consider surge loads in generator capacity, Capacity as described above.
  • Page 11: Maintenance

    Maintenance PRODUCT Some adjustments will need to be made periodically to properly maintain your generator. SPECIFICATIONS All adjustments in this section should be made at least once each season.Follow the requirements in the "Maintenance Schedule" chart shown below in Figure I I. Generator Specifications NOTE: Once a year you should clean or replace the spark...
  • Page 12 Section 5: Maintenance To Clean the Generator • Remove oil drain plug, sealing washer, and oil filler cap. Drain oil completely into a suitable container. • Use a damp cloth to wipe exterior surfaces clean. • Install oil drain plug and sealing washer. Tighten securely. •...
  • Page 13: Storage

    Section 5 & 6: Maintenance & Storage • Install the clean screen in the reverse order of removal. To clean or replace air filter element: • Loosen the air cleaner cover screws,remove the air NOTE: If you useyour generator on any forest-covered, brush-covered or grass-covered unimprovedland, it must cleaner cover, and remove the element (see item have a spark arrester installed.The spark attester must be...
  • Page 14 WARNING! Contact with a hot engine or exhaust system can cause serious burns or fires. Let the engine coot before transporting or storing the generator. Take care to not drop or strike the generator when transporting. DO NOT place heavy objects on the generator.
  • Page 15: Troubleshooting

    Troubleshooting TROUBLESHOOTING Problem Cause Correction Reset circuit breaker. One of the circuit breakers is open. No AC or DC output Fault in generator. Contact Authorized service facility. is available but Poor connection or defective cord set. Check and repair. Connected device isbad. Connect another device that is in engine is running.
  • Page 16: Wiring Diagram

    Wiring Diagram WIRING DIAGRAM EN@ZNE 6LTERN6TDR YELLOW GRI]UI_ BLUE _LUE GREE_ BL_CK BL_K BL_CK YELLOW _HZrE CZRCUK BRE_KEe YELLOW...
  • Page 17: Replacement Parts

    Exploded Views and Parts Lists EXPLODED VIEW PARTS LIST - HAIN UNIT 27., _./13 25\_e'23 Item Part # Description Item Part # Description ENG, MITSUB, 2.4HP 187392GS SCREW 187378GS ROTOR 187383GS BASE,GEN 187411GS 187390GS BOLT, FLNG 187379GS STATOR 187385GS MNT, VIBR 187430GS 187427GS SCREW...
  • Page 18 Section 9: Exploded Views and Parts Lists EXPLODED VIEW PARTS LIST - HAIN UNIT 11_e Item Part # Description Item Part # Description 187436GS CAP, FUEL 187371AGS BOTTLE, OIL 187439GS PACKING, TANK 192413GS DECAL, LWR PANEL 187438GS FLTR, FUEL 187773GS COVER, OIL FILL 187769GS U-PACKING...
  • Page 19 Section 9: Exploded Views and Parts Lists EXPLODED VIEW PARTS LIST - ENGINE Cylinder Block, Cylinder Head Item Part # Description 187380GS BLOCK, CYL 187386GS ASSY,GOV, GEAR 187387GS SLIDER, GOV 187391GS SHFT, GOV 187393GS PLUG, DRAIN 187394GS SEAL, OIL 187395GS BRG, BALL 187400GS WSHR, CYLBLOCK...
  • Page 20 Section 9: Exploded Views and Parts Lists EXPLODED VIEW PARTS LIST - ENGINE Crankcase Cover, Crankshaft/Camshaft Item Part # Description 187394GS SEAL,OIL 187473GS CVR, CRANKCASE 187474GS DIPSTICK, OIL 187475GS O-RING, DIPSTICK 187477GS BRG, PTO 187478GS BOLT, CRANKCASE CVR 187428GS PIN, DWL 187479GS GSKT, CRANKCASE CVR Item...
  • Page 21 Section 9: Exploded Views and Parts Lists EXPLODED VIEW PARTS LIST - ENGINE Piston/Rod, Magneto/Flywheel, Air Cleaner Item Part # Description 187526GS ROD, CNNCTNG, STD 187527GS ROD, CNNCTNG, US.25 187528GS ROD, CNNCTNG, US.50 187529GS BOLT, CNNCTNG ROD 187530GS ASSY,PSTN, STD 187531GS ASSY,PSTN, OS.25 187532GS...
  • Page 22 Section 9: Exploded Views and Parts Lists EXPLODED VIEW PARTS LIST - ENGINE Carburetor, Control/Linkages Item Part # Description 187469GS CARB, COMPLETE 187471GS JET,MAIN 187476GS SHFT,THROTTL 187480GS VLV,NEEDLE 187482GS CLIP,CARB 187483GS PIN, CARB 187485GS VLV,THRTTL 187491GS HHCS, CARB \ 20 187493GS VLV,CHOKE _-29...
  • Page 23 Section 9: Exploded Views and Parts Lists EXPLODED VIEW PARTS LIST - ENGINE Fan Cover, Recoil Starter, Oil Sensor Item Part # Description 187521GS CVR, FAN 187522GS CVR, FAN 187523GS CVR, FAN 187524GS BOLT, FAN CVR _:_, +,_is_; Item Part # Description ..
  • Page 24 Section 9: Exploded Views and Parts Lists EXPLODED VIEW PARTS LIST - ENGINE Lead Wires, Muffler, Gasket Set Item Part # Description 187571GS WIRE, LEAD 187572GS PLUG, SPARK 187574GS TIEWRAP, LEAD WIRE 187573GS CAP, PLUG 187575GS WIRE, LEAD Item Part # Description 187449GS NUT, FLNG...
  • Page 25: Emmision Control System Warranty

    EMISSION CONTROL SYSTEM WARRANTY Briggs & Stratton Power Products (BSPP), California Resources Board (CARB) United States Environmental Protection Agency (U.S.EPA) Emission Control System Warranty Statement (Owner's Defect Warranty Rights and Obligations) EMISSION CONTROL WARRANTY COVERAGE IS Cold start enrichment system APPLICABLE TO CERTIFIEDENGINES PURCHASED IN Carburetor and internal parts CALIFORNIA IN 1995 AND THEREAFTER WHICH ARE USED...
  • Page 26 Reglas de Seguridad TABLA DE CONTENIDOS INSTRUCCIONES DE SEGURIDAD Reglas De Seguridad ......26-28 Conozca Su Generador ......para advertir Este es el simbolo at usuario de alerta de un posible de seguridad. riesgo Sirve para Ensamblaje ........30-3 I su integridad fisica.
  • Page 27 Secci6n 1: Instrucciones de Seguridad PELIGRO ADVERTENCIA Opere el generador SOLAMENTE al aire libre. CUANDO AI_IADA COMBUSTIBLE Mantenga al menos 2 pies de espacio libre alrededor del generador, Apague el generador (posici6n OFF) y d6jelo enfriar al menos por para la adecuada ventilaci6n. 2 minutos antes de remover la tap_ de la gasolina.Atloje la tapa NO opere el generador dentro de un edificio o lugar cerrado, induyendo lentamenta para dejar que la presi6n salgadel tanque.
  • Page 28 Secci6n 1: Instrucciones de Seguridad PRECAUCION ADVERTENCIA Vea "No sobrecargue generador" en la p_gina34. Encienda su generador y deje que el motor se estabilice antes de conectar las cargas el_ctricas, ;ENERADOR Conecte las cargas el_ctricas en la posici6n de apagado (OFF), luego Siempre desconecte el alambre de la bujla y col6quelo donde no encienda (ON) para su operaci6n.
  • Page 29 Caracteristicas ¥ Controles CONOZCA SU GENERADOR Lea este manual del propietario y las reglas de seguridad antes de operar su generador. Compare las ilustraciones con su generador para familiarizarse con la ubicaci6n de los diferentes controles y ajustes. Conserve este manual para referencias futuras.
  • Page 30 Si el nivel de aceite no se encuentra en el punto de MONTAJE desbordamiento del cuello del rellenador de aceite, llene lentamente el motor con el aceite recomendado. Contenido del Empaque Reinstale la tapa del rellenador de aceite y suj_telo de forma Si cualquiera de las partes no est_n presente o se encuentran segura.
  • Page 31 Operaci6n CONEXION A TIERRA Gire la v_lvula de combustible a la posici6n "Open" ("ABtERTO") (completamente en la direccibn de las manecillas GENERADOR del reloj) (Figura 19). El C6digo El_ctrico Nacional exige que el bastidor y las partes ililllllllilVilllilll|lll {Itllllllll [_i Itll/illlllll externas conductoras de electricidad del generador se encuentren conectadas adecuadamente a una tierra flsica aprobada.
  • Page 32 Secci6n 4: Operaci6n funcionar el motor en greas con ventilad6n defidente. El PRECAUCI_N! iPeligroal respirar! NUNCA haga ADVERTENCIA! NO permita que se fume, llamas abiertas, chispas o cualquier otra fuente de calor alrededor escapecontiene monbxido de carbono, un gas inodoro y de la baterla.
  • Page 33 Secci6n 4: Operaci6n Arranque el motor. Deje que el motor fundone mientras la Clavija Accesoria de 12 Voltios baterfa se recarga. 8.3 Amper,os Cuando la bateria haya cargado, apagueel motor (yea "Parado Este recept_culo le permite recargar una bateria de 12 Voltios del Motor"...
  • Page 34 Secci6n 4: Operaci6n NO SOBRECARGUE GENERADOR Conecte y encienda la prbxima carga. De nuevo, permita que el generador se estabilice. Capacidad Repita los pasos 4 y 5 para cada carga adicional que usted tenga. Usted debe asegurarse que su generador puede proveer el suflciente vataie calificado (cuando est6 funcionando) y de carga...
  • Page 35 Mantenimiento ESPECIFICACIONES Ser_ necesario realizar algunos aiustes de manera peri6dica para mantener de forma apropiada a su generador. PRODUCTO Todos los ajustes en esta secci6n deber_n hacerse pot Io menos una vez cada temporada. Cumpla con los requisitos en el cuadro Especificaciones del Generador "Programade Mantenimiento"...
  • Page 36 Secci6n 5: Mantenimiento Instalela clavija de drenaie y la arandela. Apriete con fuerza. Para Limpiar el Generador Rellene con el aceite recomendado y verifique su nivel. Utilice unafranela h_meda para limpiar las superficies externas. Consulte la p_gina 30 para conocer cugles son las Un cepillo de cerdas podria usarse para remover los residuos recomendaciones de aceite.
  • Page 37 Secci6n 5 & 6: Mantenimiento & Almacenamiento Para limpiar o reemplazar el elemento del filtro de aire: NOTA: Si usa su generador en un terreno boscoso, cubierto por maleza o por c_sped, debe tener un amortiguador de chispas Afloie los tornillos de la cubierta del filtro de aire, remueva la instalado.
  • Page 38 Almacenamiento PRECAUCI_N! El contactocon motor 0 sistema de escape cuando est_n calientes,puede causar quemaduras graves o incendios. Permita que el motor se enfrie antes de transportar o almacenar el generador. Tenga cuidado de no deiar caer ni golpear el generador cuando Io transporte.
  • Page 39 Notas NOTAS...
  • Page 40 Notas NOTAS...
  • Page 41 Diagnosticos de Averias DIAGNOSTICO Y REPARACI( N DE AVERiAS Soluci6n Problema Causa uno de los cotacircuitos est_ abierto. Reaiuste el cortacircuito. Falla en el generador. P6ngase en contacto con el servicio El motor est_ funcionando t_cnico autorizado. pero no existe salida de AC Mala conexi6n o juego de cordones...
  • Page 42 GARANTIA DEL SISTEMA DE CONTROL DE EMISIONES Briggs & Stratton Power Products (RSPP), California Air Resources Board (Consejo de Recursos sobre el Aire de California, CARB, por sus siglas en ingles) y United States Environmental Protection Agency (Agencia de Protecci6n Ambiental de EE.UU., EPA, por sus siglas en ingles).
  • Page 43 POLJTICA PARA EL PROPIETARIO DE EQUIPOS TROY-BILT® Efectiva desde el I ro de Enero, 2003 GARANTIA LIMITADA "Troy-BiltO es una marca registrada de MTD baio licencia de Briggs & Stratton Power Products. Briggs & Stratton Power Products reparar_ o sustituir_...
  • Page 44 TROY-BILT® OWNER WARRANTY POLICY Effective January I, 2003 LIMITED WARRANTY "Troy-Bitt® is a registered trademark of MTD and is used under license to Briggs & Stratton Power Products. Briggs & Stratton Power Products will repair or replace, free of charge, any part, or parts of the equipment _ that are defective in material or workmanship or both.

Table of Contents