Troy-Bilt 1925 Owner's Manual page 12

Briggs & stratton
Hide thumbs Also See for 1925:
Table of Contents

Advertisement

Available languages

Available languages

5ectbn
4: Opecatbn
[ 20 Vok AC, 20 Amp,
Duple×
Each dupiex recepgacie (Figure i 3) is protected
against
overioad by a push-to-reset
circuit breaker.
The maximum
bad on each outlet
is 20 Amps.The
maximum
toga[ bad
on both
yellow
wire
outlets
or both
biack wire
outiets
is 30 Amps.
[NOTE:
Follow
ali safety precautions
when
connecting
any
extension
cord
or device
to the generator.
RECEPTACLES
CAUTION
o NEVER attempt to power a device requiring more
amperage than generator
or recepgacie can suppiy.
o DO NOT overioad the generator. See "Don't
Overioad
Generator".
Use each recepgacie to operate
[20VoHtAQ
singie-phase,
60 Hz electrka[
loads requiring up to 2,400 watts (2A kW)
at 20 Amps of current. Use cord sets that are rated for
[ 25 Voit AC [oads at 20 Amps (or greater).
[ 201240 VoUt AC, 30 Amp,
Locking
Receptacle
Use a NEMA L14-30 piug with this receptacHe. Connect a
4-wire
cord set rated for 250Voit AC [oads at 30Amps
(or
greater) (Figure [4).You can use the same 4-wire
cord if
you plan to run a i20Voit
load.
[ 2 Volt
DC,
[ 0 Amp
Receptacle
This receptacle allows you to recharge a [2Vok
automotive
or utility styie storage
battery
with the battery
charge
cabies provided
(Figure
12).
This receptacle
can not recharge
6Voit
batteries
and can
not be used to crank
an engine
having
a discharged
battery.
See the section
"Charging
a Battery"
(page [ 0) before
attempting
to recharge
a battery.
4oWire
Cord Set
/
(Neutral)
Y (Hot)
|
X (Hot)
NEMA
LI 4-30
/-7L7 Ground (Green)
This recepgacie powers
i20/240VoitAC,
60 Hz, single
phase loads requiring up to 7,200 watts of power (7.2 kW)
at 30 Amps for 120Volts or 240Volts.The
outlet is
protected
by a rocker
switch circuit breaker.