Troy-Bilt 1925 Owner's Manual
Troy-Bilt 1925 Owner's Manual

Troy-Bilt 1925 Owner's Manual

Briggs & stratton
Hide thumbs Also See for 1925:

Advertisement

Available languages

Available languages

Quick Links

O
I
I
Owner's Manual / Manual del Propietario
Portable
Generator
/ Generador
Port_til
Model / Modelo 01925
IMPORTANT:
READ
SAFETY
RULES AND
INSTRUCTIONS
CAREFULLY
IMPORTANTE:
LEYO
LA SEGURIDAD
LAS ORDENESY
LAS INSTRUCCIONES
DETENIDAMENTE
Questions? Preguntas?
Helpline
- 1-888-611-6708
M*F 8-5 CT
Troy-Bilt_ isa registeredtrademarkof MTD and isusedunder licenseto Briggs& StrattonPower Products.
Troy-Bilt_ es una marcaregistradaregistrada de MTD y se usaabaio licencia a Briggs& Stratton PowerProducts.
BRIGGS
& STRATTON
POWER
PRODUCTS
GROUP,
LLC
I!!!!U!!UU! EFFERSON,W,
SCONS,N,U.S.A
0
3
Printed in USA
Manual No. 192472GS Revision 3 (09/16/2003)

Advertisement

Table of Contents
loading

Summary of Contents for Troy-Bilt 1925

  • Page 1 ,® Owner's Manual / Manual del Propietario Portable Generator / Generador Port_til Model / Modelo 01925 IMPORTANT: READ SAFETY RULES AND INSTRUCTIONS CAREFULLY IMPORTANTE: LEYO LA SEGURIDAD LAS ORDENESY LAS INSTRUCCIONES DETENIDAMENTE Questions? Preguntas? Helpline - 1-888-611-6708 M*F 8-5 CT Troy-Bilt_ isa registeredtrademarkof MTD and isusedunder licenseto Briggs&...
  • Page 2: Table Of Contents

    Safety Rules TABLE OF CONTENTS SAFETY RULES Safety Rules........Know Your Generator ......his is the safety alert symbol. It is used to alert you to potential personal injury hazards. Assembly ........Obey all safety messages that follow this Operation ........8-13 Maintenance .........
  • Page 3: Safety Rules

    Section 1: Safety Rules DANGER WARNING Operate generator ONLY outdoors. WHEN ADDING FUEL Keep at least 2 feet of clearance on all sides of generator for Turn generator OFF and let it cool at least 2 minutes before adequate ventilation. removing gas cap.
  • Page 4 Section 1: Safety Rules CAUTION WARNING See"Don't Overload Generator" on page 13. Start generator and let engine stabilize before connecting electrical loads. ;ENERATOR Connect electrical loads in OFF position, then turn ON for Disconnect the spark plug wire from the spark plug and place operation.
  • Page 5: Know Your Generator

    Features and Controls KNOWYOUR GENERATOR Read this owner's manual and safety rules before operating your generator. Compare this illustrationwith your generator to familiarize yourself with the locationsof various controls and adjustments. Savethis manualfor future reference. Oil Fill Cap FuelTank Rocker Switch Circuit Breaker Air Cleaner Circuit...
  • Page 6: Assembly

    ASSEMBLY To install: Cut off tie wrap securing loose end of negative (black) Your generator requires attachment of the negative battery cable. cable and is ready for useafter it has been properly Attach negative battery cable with 5/16" x 3/4" screw serviced with the recommended oil and fuel.
  • Page 7: Assembly

    Section 3: Assembly BEFORE STARTING Attach Handle You will need two I/2" or 13 mm wrenches to attach the ENGINE handle. Attach handle to right side of generator frame (viewing Add Engine Oil and Fuel unit from front), as shown in Figure 2, with a 60 mm capscrew,flat washers, nylon washers, and lock nut.
  • Page 8: Operation

    Operation USING THE GENERATOR OPERATING G EN ERATO R System Ground CAUTION The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles.The system ground is connected to the AC neutral wire (see "Equipment Description", earlier in this manual).
  • Page 9 Section 4: Operation Connect the other RED jumper cable clamp to the Jump Start Procedure starting battery's POSITIVE battery terminal. If the generator's starting battery fails, usethe following Connect the BLACK jumper cable clamp to the instructions to jump start your generator.You can jump starting battery's NEGATIVE battery terminal.
  • Page 10 Section 4: Operation Connect battery charge cable clamp with black handle Charging a Battery to the negative (-) battery terminal (Figure 6). Your generator hasthe capability of recharging a discharged Start engine. Let engine run while battery recharges. 12Volt automotive or utility style storage battery. DO NOT use the unit to charge any 6Vott batteries.
  • Page 11 Section 4: Operation COLD WEATH G EN ERATO R ADAPTER OPERATION CORD Under certain weather conditions (temperatures below The generator is equipped with a 25' generator adapter cord 40°F [4°C] and a high clew point), your generator may set designedfor a 240Volt, 30 Amp grounded neutral circuit experience icing of the carburetor and/or the crankcase (Figure9).The generator adapter cord set provides a breather system.
  • Page 12 Section 4: Operation RECEPTACLES Use each receptacle to operate 120Volt AC, single-phase, 60 Hz electrical loadsrequiring up to 2,400 watts (2.4 kW) at 20Amps of current. Use cord sets that are rated for CAUTION 125Volt AC loads at 20 Amps (or greater). 120/240 Volt AC, 30 Amp, Locking NEVER attempt to power a device requiring more...
  • Page 13: Operation

    Section 4: Operation DON'T OVERLOAD Plug in and turn on the next load. Again, permit the generator to stabilize. G EN ERATO R Repeat steps 4 and 5 for each additional load. NEVER add more loads than the generator capacity.Take special care to consider surge loads in generator capacity, Capacity as described above.
  • Page 14: Maintenance

    Maintenance GENERAL MAINTENANCE After oil hasdrained, reinstall the oil drain plug. Remove the oil drain tray from under the oil drain plug RECOMMENDATIONS and clean up any spilled oil. Changing Oil Filter The Owner/Operator is responsible for making sure that Placethe half moon notch in the oil drain tray under all periodic maintenance tasks are completed on a timely the oil filter (Figure 15).
  • Page 15: Maintenance

    Section 5: Maintenance Generator Maintenance Data Tag Generator maintenance consists of keeping the unit clean Data tag informationis very important if you need hetp and dry. Operate and store the unit in a clean dry from our Customer Service Department or an authorized service d ealer.
  • Page 16: Storage

    STO RAG E Engine Storage manual for engine owner's instructions. The generator should be started at least once every seven claysand allowed to run at least 30 minutes. If this cannot Other Storage Tips be done and you must store the unit for more than •...
  • Page 17: Troubleshooting

    Troubleshooting TROUBLESHOOTING Problem Cause Correction One of the circuit breakers is Reset circuit breaker. open. Contact Authorized service Fault in generator. facility. No AC output is available, but Poor connection or defective Check and repair. generator is running. cord set. Connect another device that is in Connected device is bad.
  • Page 18 Wiring Diagram and Schematic SCHEMATIC 3!TR c L > AUTI ] 10 ANP RESET ,.AMP ,_wc B_2TTE_ IWITCH _ppLAURGK iiiiDF IGNITIBN REGULATBR VBLTAGE WHITE FIELD PBWER PBWER PI 4 _22120V20S_ _'_44A25AIp BRASS SCRE_ [20' SILVER SCREW GREEN TLR] SCREW WHI] ]28/248V...
  • Page 19: Schematic/Wiring Diagram

    Section 8: Wiring Diagram and Schematic WIRING DIAGRAM BATTERY SPARK PLUG CARB FUEL SHUT BFF...
  • Page 20 Exploded Views and Parts Lists EXPLODEDVIEW- MAIN UNIT 14--...
  • Page 21 Section 9: Exploded Views and Parts Lists PARTS LIST - MAIN UNIT Description Item Part # Description Item Part # HANDLE (Includes Item 43) PI91821GS CRADLE PI91822GS NUT, Nylok P|93086GS CRADLE,Top 49820GS WASHER 192368GS ASSY, D C Control Panel(see page23) 22145GS SCREW 193263GS...
  • Page 22 Section 9: Exploded Views and Parts Lists & PARTS LIST AC CONTROL PANEL EXPLODED VIEW \\\\\ \\\\ Item Part # Description 188914GS COVER, Lid, Controt Panel 192273BGS CONTROL PANEL,Compact 189167GS CLIP,Hinge Pin Retainer 189182GS SPRING, Hinge, Pin 189166GS PIN, Hinge, Cover, Compact 68759GS OUTLET, 120V,20A, Duplex 189165GS...
  • Page 23 Section 9: Exploded Views and Parts Lists DC CONTROL PANEL EXPLODED VIEW & PARTS LIST Item Part # Description 192367GS PANEL, DC Control 191015GS SWITCH, SRS 191016GS KNOB, SRSSwitch 192466GS ASSY, J ack,Coaxial 186133GS CAR Battery Charge 90418GS OUTLET, 12VDC, Snap 192945GS PLATE,Switch Key 87962GS...
  • Page 24 Section 9: Exploded Views and Parts Lists ALTERNATOR EXPLODED VIEW & PARTS LIST Item Part # Description 186059GS ADAPTER, Mounting, Alternator 192171GS ROTOR 192186AGS STATOR 186060GS RBC, (with O-Ring p/n 189197GS) 86308KGS SCREW 66386GS ASSY,Holder, Brush 66849GS SCREW 22694GS RECEPTACLE, 6 pin 81917GS PIN, Roll 19105lAGS...
  • Page 25: Notes

    Notes NOTES...
  • Page 26 Reglas de Seguridad TABLA DE CONTENIDOS REGLAS DE SEGURIDAD ReglasDe Seguridad ........ 26-28 Conozca Su Generador ........ para advertir al usuario de un posible riesgo para Este es el simbolo de alerta de seguridad. Sirve Ensamblaje........30-3 I su integridad fisica. Siga todos los mensajes de Funcionamiento ........
  • Page 27 Secci6n 1: Reglas de Seguridad PELIGRO ADVERTENCIA Opere el generador SOLAMENTE al aire libre. CUANDO AI_IADA COMBUSTIBLE Mantenga al menos 2 pies de espado libre alrededor del generador, Apague el generador (posici6n OFF) y d_jelo enfriar al menos por para la adecuada ventilaci6n. 2 minutos antes de remover la tapa de la gasolina.Afloie la tapa NO opere el generador dentro de un edificio o lugar cerrado, incluyendo lentamente para deiar que la presi0n salga del tanque.
  • Page 28 Secci6n 1: Instrucciones de Seguridad PRECAUCION ADVERTENCIA Vea "No sobrecargue generador" en la p_gina 38. Encienda su generador y deje clue el motor se estabilice antes de conectar las cargas el/actricas. ;ENERADOR Conecte las cargas el_ctricas en la posici6n de apagado (OFF), luego Siempre desconecte el alambre de la bujla y col6quelo donde no encienda (ON) para su operaci6n.
  • Page 29 Caracteristicas ¥ Mandos CONOZCA SU GENERADOR LEA ESTE MANUAL DEL PROPIETARIOY LAS REGLAS DE SEGURIDAD ANTES DE OPERAR SU GENERADOR. Compare las ilustraciones con su Generador para familiarizarse con las ubicaciones de los diferentes controles y ajustes. Conserve este manual para referencias futuras.
  • Page 30 Para instalar: MONTAJE Corte el cablecito que est_ aguantando el cable negro, para Su generador requiere de ciertos procedimientos de montaie y poderlo usar. solo estar_ listo para ser utilizado despu_s de haberle Fije el cable negativo de la baterta con el 5/16" x 3/4" tornillo suministrado servicio con el combustible y aceite recomendados.
  • Page 31 Secci6n 3: Montaje ANTES DE DARLE ARRANQUE Fije el Asa MOTOR Necesitar6 dos Ilaves inglesas de 13 mm o I/2" para fiiar el asa. Fije el asa al lateral derecho del bastidor del generador (visto desde la parte delantera de la unidad), como se muestra en la Agregar Aceite al Motor...
  • Page 32 Operaci6n DEL GENERADOR OPERANDO EL GENERADOR PRECAUCION Tierra del Sistema El generador dispone de una conexi6n a tierra del sistema que conecta los componentes del bastidor a los terminales de tierra de los enchufes hembra de salida de CA. La tierra del sistema Vea "No sobrecargue generador"...
  • Page 33 Secci6n 4: Operaci6n Conecte la otra pinza del cable de puente ROJO al terminal Arranclue Procedimiento Puente Posmvo de la bateria de arranque. Si fa[la la bateria de arranque del generador, siga estas Conecte la otra pinza del cable de puente NEGRO al instruccionespara arrancarlo en puente.
  • Page 34 Secci6n 4: Operaci6n Conecte el sujetador del cable de carga de la bateria que Carga de la Bateria tiene la manija negra al terminal negativo (-) de la bateria Su generador tiene la capacidad de recargar baterlas descargadas (Figura 22). de acumuladores tipo servicio o automotriz de 12Voltios.
  • Page 35 Secci6n 4: Operaci6n OPERACI( N DURANTE Aseg_rese que existe un espacio mfnimo de dos pies entre el laclo abierto de la caja y el obieto m_s cercano. CLIMA FRiO Coloque la parte abierta fuera clel viento y otros elementos. Baio ciertas concliciones ambientales (temperaturas pot debajo de La cobertura cleberfa aguantar el calor suficiente creaclo por los 40-_F[4-_C]y un punto alto Dew), su generador puede el generaclor para prevenir problemas.
  • Page 36 Secci6n 4: Operaci6n RECEPTACULOS JUEGO DE CABLES ADAPTADOR DEL GENERADOR Tomacorrientes 12 Voltios El generador est_ equipado con un Juego de Cables del Adaptador Este tomacorriente le permite recargar una bateria de del Generador de 25 pies,disefiado para un circuito neutro a almacenamiento tipo servicio o automotriz de 12Voltios tierra de 240 voltios, 30 Amperios (Figura 25).
  • Page 37 Secci6n 4: Operaci6n 120/240 Voltios 30 Amp, Receptgculo 120 Volt AC, 20 Amp, Recept_culos Dobles de Seguridad Cada recep_culo (Figura 27) est,i protegido en contra de sobrecargas por un corto-circuitos de, del tipo "empuje para Use un tap6n NEMA LI4-30 con este recept,iculo. Conecte un reposicionar".
  • Page 38 Secci6n 4: Operaci6n NO SOBRECARGUE Conecte y encienda la pr6xima carga. De nuevo, permita que el generador se estabilice. GENERADOR Repita los pasos4 y 5 para cada carga adicional que usted tenga. Capacidad NUNCA afiada mgs cargas sobre la capacidad del generador. Usted debe asegurarse que su generador puede proveer el Tome una atenci6n especial en considerar lascargas de corriente suficiente vataje calificado (cuando est_ funcionando) y de carga...
  • Page 39 Mantenimiento RECOMENDACIONES Una vez vaciado el aceite, vuelva a colocar el tap6n de vaciado de aceite. GENERALES Retire la bandeja de vaciado de aceite de debaio del tap6n y MANTENIMIENTO limpie los restos de aceite. Cambio del Filtno de Aceite El propietario I operador es responsable...
  • Page 40 Secci6n 5: Mantenimiento Mantenimiento del Generador Placa de Caracterlsticas Localice la placade caracterlsticas del generador y copie la El mantenimiento del generador consiste en conservar la unidad informacibnen el espacio disponib[e a continuacibn. Esta limpia y seca.Opere y almacene la unidad en un ambiente limpio y informacibnes fundamental para poder recibir ayuda de nuestro seco donde no ser_ expuesta a[ polvo, suciedad,humedad o departamento de servicio al cliente o de un distribuidor de...
  • Page 41 Almacenamiento Almacenando el Motor ALMACENAMIENTO Consulte el manual del propietario del motor para las El generador deber_ ser encendido al menos una vez cada siete instruccionesde cbmo preparar adecuadamente el motor para su dfas y deber_ dejarlo funcionar al menos durante 30 minutos. Si almacenamiento.
  • Page 42 Diagnosticos de Averias DIAGNOSlTICOS DE AVERiAS Problemo Causa Accion El interruptor autom_ico de circuito Reposicione el interruptor. est_ abierto. Conexi6n mal o defectuosa del iuego Revise y repare. El motor est& funcionando pero no de cables. existe salida de AC disponsible. Conecte otro dispositivo que est_ El dispositivo conectado...
  • Page 43 POLJTICA PARA EL PROPIETARIO DE EQUIPOSTROY-BILT® Efectiva desde el Iro de Enero, 2003 GARANTIA LIMITADA "Troy-BiltO es una marca registrada de MTD bajo licencia de Briggs & Stratton Power Products. Briggs & Stratton Power Products reparar_ o sustituir_ sin cargo alguno cualquier componente del equipo** que presente defectos de materiales y/o mano de obra.
  • Page 44: Warranty

    TROY-BILT® O WNER WARRANTY POLICY Effective January I, 2003 LIMITED WARRANTY "Troy-Bitt® is a registered trademark of MTD and is used under license to Briggs & Stratton Power Products. Briggs & Stratton Power Products will repair or replace, free of charge, any part, or parts of the equipment** that are defective in material or workmanship or both.Transportation charges on parts submitted for repair or replacement under this warranty must be borne...

Table of Contents