Maximum Capacity
Hardware Configuration
– Two disk array controllers connected directly to host Fibre Channel adapters
– Five disk enclosures with ten 73 GByte disks each (50 disks total)
– Disk enclosures configured for full-bus mode (one SCSI channel per enclosure)
Volume Group Configuration
– Ten RAID 5 volume groups, each comprising five disks (4 data + 1 parity)
– Each disk in a volume group is in a separate enclosure.
High Availability
– Handles a single disk failure, single disk enclosure/BCC failure, single channel
failure, or a single controller failure
– Expansion requires powering down the disk array, and adding an additional disk
enclosure and cabling
Disk Capacity
– Maximum capacity 3650 GBytes
– Usable capacity 2920 GBytes
Recommended Disk Array Configurations