Errors During / After Firmware Download
Different patterns are displayed after downloading firmware. The patterns are shown in
Table
29.
Note that a
Note
.
Table 29
Firmware Download LEDs
Error
Download file is lacking header record.
Download file header fails checksum test.
Download file header contains unexpected download type.
The user should attempt to download a known good file.
Intermodule error call to flash function passed bad flash type. There is
a mismatch between the Boot Firmware and the Application Firmware.
The user must download matched versions of both controller
Bootware and controller Application Firmware.
Invalid address in flash device.
Unable to fully erase boot flash segments (bad voltage or device).
Replace the controller board.
Unable to fully erase file flash segments (bad voltage or device).
Replace the controller board.
Unable to program boot flash after 3 cycles of erase and write.
Replace the controller board.
Unable to program application file flash after 3 cycles of erase and
write. Replace the controller board.
Software load failure. There is a mismatch between the Boot Firmware
and the Application Firmware. The user must download matched
versions of both code types.
! ! ! ! indicates the LED is On or Flashing.
LED Pattern
0x61
0x64
0x65
0x67
0x91
0x92
0x95
0x96
0x97
0x98
0xE6
Controller Enclosure Troubleshooting