MAINTENANCE
3) Check for evidences of excessive
condensation, such as water droplets
forming in the inner liner, and subsequently
dripping out the joints, Continuous
condensation can cause corrosion of caps,
pipe, and fi ttings. It may be caused by having
excessive lateral runs, too many elbows,
and exterior portions of the system being
exposed to cold weather.
4) Inspect joints, to verify that no pipe
sections or fi ttings have been disturbed,
and consequently loosened. Also check
mechanical supports such as Wall Straps,
or plumbers' tape for rigidity.
P36E-4 Zero Clearance Direct Vent Gas Fireplace

REMOVING VALVE

1) Shut off the gas supply.
2) Remove the louvers (and bay door if it is
on).
3) Open the fl ush door and remove the door.
4) Remove the logs.
5) Remove the burner/grate assembly by
removing the two screws and then lift the
burner assembly out.
Diagram 1: Remove the left and right screws
and then lift out the burner/grate assembly.
6) Disconnect the inlet gas line.
7) Disconnect the EV1, EV2, and ground wires
from the valve - as shown below.
EV1
8) Remove the rear log stand by removing the
2 screws.
9) Remove the 10 screws securing the
valve tray assembly in place (Diagram
2) and then lift the entire assembly out
(Diagram 3).
screws
screws
Diagram 2: Rear Log Stand and
Valve Tray Assembly
10) Lift out valve tray.
11) Replace with a new a valve tray assembly
and reverse steps 9 - 1.
Ground
EV2
Rear Log Stand
Valve Tray Assembly