Regency Series Combustible Mantel Clearances - Regency P36E-NG4 Owners & Installation Manual

P36e zero clearance direct vent gas fireplace
Table of Contents

Advertisement

REGENCY
Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible
board.
Because of the extreme heat this fi replace emits, the mantel clearances are critical.
Combustible mantel clearances from top of unit are shown in Diagrams 1 & 2.
Mantel Clearances with
Flush Glass / Full Screen Doors
10
12
16
14
12
10
14"
8
6
4
2
0
30-1/2"
to floor
These drawings are to scale at 1:6 (one inch = 6 inches)
Mantel can be installed anywhere in shaded area or higher using the above scale.
Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour.
P36E-4 Zero Clearance Direct Vent Gas Fireplace
SERIES COMBUSTIBLE MANTEL CLEARANCES
®
0
8
6
4
2
Drywall
12" Mantel
7 1/2" Mantel
3 1/2"
Mantel
10"
7"
Top of
Unit
Side View
Diagram 1
Mantel Clearances
with Bay Option
10
8
6
12
16
12" Mantel
14
12
7 3/4" Mantel
10
8
13"
10"
6
4
2
0
30-1/2"
to floor
Diagram 2
INSTALLATION
0
4
2
Drywall
3 1/2"
Mantel
7"
Top of
Unit
Side View
13