OPERATING
INSTRUCTIONS
1) Read and understand these instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the glass in the door frame is
properly positioned. Never operate the
appliance with the glass removed.
5) Verify that the venting and cap are
unobstructed.
6) Ensure that the brick panels are installed.
7) Verify log placement. If the pilot cannot be
seen when lighting the unit, the logs have
been incorrectly positioned.
8) The unit should never be turned off, and on
again without a minimum of a 60 second
wait.

FIRST FIRE

The fi rst fi re in your fi replace is part of the
paint curing process. To ensure that the paint
is properly cured, it is recommended that you
burn your fi replace for at least four (4) hours the
fi rst time you use it with the fan on.
When fi rst operated, the unit will release an odour
caused by the curing of the paint, the burning
off of any oils remaining from manufacturing.
Smoke detectors in the house may go off at
this time. Open a few windows to ventilate the
room for a couple of hours.
The glass panel may require cleaning after the
unit has cooled down.
DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS HOT.
Note: When the glass is cold and the
appliance is lit, it may cause
condensation and fog the glass.
This condensation is normal and will
disappear in a few minutes as the glass
heats up.
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
During the fi rst few fi res, a white fi lm
may develop on the glass front as part
of the curing process. The glass should
be cleaned or the fi lm will bake on and
become very diffi cult to remove. Use a
non-abrasive cleaner and NEVER clean
the glass while it is hot.
52

OPERATING INSTRUCTIONS

LIGHTING
PROCEDURE
IMPORTANT
To ignite or reignite the pilot, you
must fi rst remove the glass door.
1) Press and release on ON/OFF button once
on the remote control or ON/OFF switch.
2) After approximately 4 seconds the spark
ignition system will spark for 60 seconds to
light the main burner.
3) The unit will turn on.
Note: The fi rst try for ignition will last approxi-
mately 60 seconds. If there is no fl ame ignition
(rectifi cation) the board will stop sparking for
approximately 35 seconds. After wait time
, the board will start second try for ignition
by sparking for approximately 60 seconds .
If there is still no positive ignition the board
will go into lock out.
The system will need to be reset as follows:
a) Turn the system off using ON/OFF switch
or press ON/OFF button - if using optional
remote.
b) After approximately 2 seconds turn on ON/
OFF switch or press ON/OFF button if using
optional remote.
c) Repeat step 2.
SHUTDOWN
PROCEDURE
1) Turn the wall mounted switch or remote to
the "OFF" position.
2) Press "OFF" on the remote control.
3) Turn the gas control knob to the "OFF" posi-
tion to turn off the pilot.
AERATION
ADJUSTMENT
The air shutter can be adjusted by moving the
adjusting wire up or down. The wire is accessed
through the bottom louver opening. Open the air
shutter for a blue fl ame or close for a yellower
fl ame. The burner aeration is factory set but
may need adjusting due to either the local gas
supply or altitude.
Minimum Air Shutter Opening:
3/16"
Natural Gas
1/2"
Propane
CAUTION: Carbon will be produced if air shutter
is closed too much.
Note: Any damage due to carboning resulting
from improperly setting the aeration
controls is NOT covered under warranty.
Note: Aeration Adjustment should only be
performed by an authorized FPI Installer
at the time of installation or service.
Adjustment wire: Push to close or
pull to open aeration cap.
Closed - Tall yellow
Open - Short Blue
P36E-4 Zero Clearance Direct Vent Gas Fireplace